P24A & P34A Service Manual
TROUBLESHOOTING
12/17/12
8-2
Symptom: Machine Stopped
Possible Cause
Possible Remedy
Power failure or interruption
Check fused disconnect or circuit breaker
supplying power to the machine. If power has
been off, make sure the crankcase heater is
energized and there is no liquid refrigerant in
the compressor crankcase prior to restarting the
compressor. If ice is in the freezer, initiate a
manual harvest.
Circuit breaker (CB4) for control circuit
tripped
Check compressor crankcase heater, coils of
relays, contactors, starters, solenoid valves, and
thawing timer for a ground. Repair or replace
any defective part and reset circuit breaker.
Make sure there is no liquid refrigerant in the
compressor crankcase prior to restarting the
machine.
Compressor motor starter overload (1MOL)
tripped
Check for a loose connection on all motor
starter and motor terminals which could cause
excessive amp draw. Reset overload and
restart the machine, check amperage, power
supply, and head pressure. (Check TR in part
wind starts only).
Water pump, cutter motor, tower fan, tower
pump, conveyor motor, overload tripped
Check for loose connection on all terminals
which could cause excessive amp draw. Reset
the overload and manually run that particular
motor to check actual voltage and amperage
against motor rating.
Freezer water pump motor overload (2MOL)
tripped
Check for loose terminal connections and/or
defective breaker (CB2), reset the overload and
start the pump by turning the selector switch
(1SS) to “Hand”. Check voltage and amperage
against motor rating. Confirm proper rotation.
Cutter motor overload (3MOL) tripped
Check for loose terminal connections and
blown fuse, reset the overload. Clear all ice
that may have jammed cutter. Turn the selector
switch (1SS) to “Hand” and push the “Manual
Harvest” button. Check voltage and amps
against motor rating. If tripping repeats but ice
is not jammed, check the gear reducer for
resistance, cutter bearings for wear, drive gear
and ring gear for proper engagement, and
reducer motor for defect or single phasing.
Bin level control (optional) open
Adjust or replace control as required. If bin
level control is not used, make sure jumper
wire #8 and #9is installed at of the terminal
block.
Summary of Contents for TUBE-ICE P-24A
Page 1: ...12 20 12 P 24A P 34A TUBE ICE MACHINE Service Manual 5000 ...
Page 4: ...12 20 12 ...
Page 6: ...12 20 12 ...
Page 12: ...12 20 12 ...
Page 16: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 4 FIGURE 1 1 P24A Front Side Control Panel ...
Page 17: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 5 FIGURE 1 2 P24A Right Side ...
Page 18: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 6 FIGURE 1 3 P24A Back Side ...
Page 19: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 7 FIGURE 1 4 P24A Left Side ...
Page 20: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 8 FIGURE 1 5 P34A Front Side ...
Page 21: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 9 FIGURE 1 6 P34A Right Side ...
Page 22: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 10 FIGURE 1 7 P34A Back Side ...
Page 23: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 11 FIGURE 1 8 P34A Left Side Control Panel ...
Page 24: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 12 FIGURE 1 9 P24A Compressor Diagram ...
Page 28: ...P24A P34A Service Manual RECEIPT OF YOUR TUBE ICE MACHINE 12 26 12 2 4 ...
Page 115: ...P24A P34A Service Manual TABLES CHARTS 12 18 12 11 1 11 Tables Charts ...
Page 125: ...Appendix A ...
Page 128: ......
Page 130: ...i ...
Page 131: ...ii ...
Page 132: ...1 ...
Page 133: ...2 ...
Page 134: ...3 ...
Page 135: ...4 ...
Page 136: ...5 ...
Page 137: ...6 ...
Page 138: ...7 ...
Page 139: ...8 ...
Page 140: ...9 ...
Page 141: ...10 ...
Page 142: ...1 ...
Page 146: ...P24A P34A Service Manual INDEX 12 26 12 12 4 ...