P24A & P34A Service Manual
OPTIONS AND ACCESSORIES
12/18/12
10-3
Parameter
Minimum Maximum
Default
Recommended
Settings
Unit
Line Side Voltage
(Nominal Voltage)
90
650
208
Supply voltage
Volts
Under /Over Voltage
(tolerance)
6
18
12
10
%
Phase Unbalance
2
25
6
5
%
Lockout Time
(Delay on Break)
0
720
30
120
Seconds
Delay Time
(Delay on Make)
0
30
0
0
Seconds
Response Time
(Delay on Fault)
0.1
20
2
2
Seconds
Control
Off / Auto / On
Auto
On
N/A
Contactor Test
OFF
5
OFF
OFF
Volt Diff
Parameters adjustment
(in order of display)
Active display of Line Voltage (this is the default normal display)
Active display of Load Side Voltage (if connected)
Voltage Set Point
(VAC Flashes) The value may be adjusted by pressing the up and down arrows. This may be set to
the normal operating voltage of the device being protected in one volt increments.
Under/over Voltage Tolerance in %
(UNDERVOLTAGE/OVERVOLTAGE flashes)
The value may be adjusted by pressing the up and down arrows.
Imbalance Voltage Tolerance in %
(% IMBALANCE flashes) The value may be adjusted by pressing the up and down arrows.
Lockout Time in seconds
(SECONDS flashes) The value may be adjusted by pressing the up and down arrows. (This is the
delay on break timer value)
Delay time in seconds and tenths of seconds
(RESP. SECONDS flashes) The value may be adjusted by pressing the up and down arrows. This
is the time that a fault is allowed before shutdown occurs.
Control mode
(ON OFF AUTO flashes) The value may be adjusted to OFF (load will not turn on), ON (load
will turn on whenever there are not faults and timers are finished) and AUTO (Load will turn on
when there is a control input).
Contactor fault monitor mode
(CONTACTOR FAULT flashes) This option allows you to monitor the contactor and lock it out
if the line voltage and load side varies by more than 5 volts. Pressing the up and down arrows
selects off (default) or on. The load side of the contactor must be connected to the load terminals
of the DTP-3 to use this option.
Summary of Contents for TUBE-ICE P-24A
Page 1: ...12 20 12 P 24A P 34A TUBE ICE MACHINE Service Manual 5000 ...
Page 4: ...12 20 12 ...
Page 6: ...12 20 12 ...
Page 12: ...12 20 12 ...
Page 16: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 4 FIGURE 1 1 P24A Front Side Control Panel ...
Page 17: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 5 FIGURE 1 2 P24A Right Side ...
Page 18: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 6 FIGURE 1 3 P24A Back Side ...
Page 19: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 7 FIGURE 1 4 P24A Left Side ...
Page 20: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 8 FIGURE 1 5 P34A Front Side ...
Page 21: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 9 FIGURE 1 6 P34A Right Side ...
Page 22: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 10 FIGURE 1 7 P34A Back Side ...
Page 23: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 11 FIGURE 1 8 P34A Left Side Control Panel ...
Page 24: ...P24A P34A Service Manual INTRODUCTION 12 18 12 1 12 FIGURE 1 9 P24A Compressor Diagram ...
Page 28: ...P24A P34A Service Manual RECEIPT OF YOUR TUBE ICE MACHINE 12 26 12 2 4 ...
Page 115: ...P24A P34A Service Manual TABLES CHARTS 12 18 12 11 1 11 Tables Charts ...
Page 125: ...Appendix A ...
Page 128: ......
Page 130: ...i ...
Page 131: ...ii ...
Page 132: ...1 ...
Page 133: ...2 ...
Page 134: ...3 ...
Page 135: ...4 ...
Page 136: ...5 ...
Page 137: ...6 ...
Page 138: ...7 ...
Page 139: ...8 ...
Page 140: ...9 ...
Page 141: ...10 ...
Page 142: ...1 ...
Page 146: ...P24A P34A Service Manual INDEX 12 26 12 12 4 ...