5.1
Capturing and loading configurations
Capturing Vocality configuration files is useful for speeding up the configuration of
identical multiple units. You can configure and test a single unit, then the configuration
can be captured and uploaded to other units.
When you are troubleshooting, it is helpful to capture the current configuration and
send that information along with details of the problem that has been observed.
5.1.1 Equipment
The only equipment you require is your unit, a supervisor cable and a PC running a
suitable terminal program such as HyperTerminal (configured for 9600bps, 8 data bits,
no parity, one stop bit, no flow control).
Optional setting: If you experience any difficulties when attempting to paste the
configuration back into a unit, you should set the 'line delay' to 50 milliseconds under
ASCII Setup (see Figure 5-2 ).
5.1.2 Configuration
Connect the PC to your unit using the supervisor cable and open up a terminal session.
Connection to most units is through serial connections, but can be through Telnet / SSH
connections if configured.
Figure 5-1 Port settings