Eccellenza Touch
VKI Publication #100308-003
79
Message Displayed
Code
Condition
Action(s) Required
Coffee Dispensers current is over
safety level
M6,
M7
Coffee dispenser motor current has
exceeded the maximum operating
level.
1 - Check to see if the coffee
dispenser motor is jammed.
2 - Reboot the machine.
3 - If message persists, replace the
coffee dispenser motor.
Coffee Dispensers current is under
minimum operation level
M6,
M7
Coffee dispenser motor current is
below the minimum operating level.
1 - Check the wiring and connections
to the coffee dispenser motor.
2 - The coffee dispenser may not be
engaged with the dispenser motor.
3 - The coffee dispenser motor
coupling may need to be replaced.
4 - If message persists, replace the
coffee dispenser motor.
Coffee Dispensers Over Current
Standby
Z99
The coffee dispensers current sum
was over the configured stand by
operation level.
1 - Clear the message.
2 - Reboot the machine.
Coffee Grinder Over Current Standby
G1
The grinder current was over the
stand by operation level.
1 - Clear the message.
2 - Reboot the machine.
CUP LIGHT LED #1 is not detected/
CUP LIGHT LED #2 is not detected
S1, S2
Cup Light LED #1 or #2 is shorted.
1 - Replace LED/harness.
Fan is not present or has abnormal
operation
K1
Fan is not present or operating
abnormally.
1 - Check fan wiring and connection
to the control board.
2 - Clean any accumulation from fan.
3 - If message persists, replace the
exhaust fan.
4 - If message persists, replace the
control board.
Grinder Fuse Fault
G1
Grinder fuse is in fault.
1 - This message resets
automatically after all critical errors
have been fixed.
Grinder Sensor Error
G1
Grinder Current Sensor is out of range. 1 - Clear the message.
2 - Reboot the machine.
Grinder's current is close to critical
level
G1
Grinder current is close to maximum
operating level. Grinder may be
drawing too much power.
1 - Check to see if the grinder is
jammed (possibly a foreign object in
the grinder heads).
2 - Check the condition of the
grinder belt.
3 - Reboot the machine.
4 - If message persists, replace the
grinder.
Grinder's current is close to minimum
operation level
G1
Grinder current is close to minimum
operating level. Grinder may not be
drawing enough power.
1 - Reboot the machine.
2 - If message persists, replace the
grinder.
Grinder's current is over safety level
G1
Grinder current has exceeded the
maximum operating level.
1 - Check to see if the grinder is
jammed (possibly a foreign object in
the grinder heads).
2 - Check the condition of the
grinder belt.
3 - Reboot the machine.
4 - If message persists, replace the
grinder.
Grinder's current is under minimum
operation level
G1
Grinder current is below the
minimum operating level.
1 - Check the condition of the
grinder belt.
2 - Check the wiring and connections
to the grinder.
3 - The grinder may need to be
replaced.