NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
is equal or greater than 0400a.
enableextled
<Not
recommended to
use this>
<boolean>
1/6
Enable/disable external IR led
* Only available when
"capability_daynight_c<0~"capability_
nvideoin"-1>_externalir > 0".
* We replace this parameter with
"ircutcontrol_illuminators_external_d
o_enabled" when the version number
(httpversion) is equal or greater than
0312a.
* We do not support this parameter
when "capability_nvideoin > 1".
* This parameter will not be used
after the version number (httpversion)
is equal or greater than 0400a.
enablewled
<Not
recommended to
use this>
<boolean>
6/6
Enable/disable built-in White led
* Only available when "
capability_daynight_c<0~"capability_
nvideoin"-1>_builtinwled > 0".
* We replace this parameter with
"ircutcontrol_illuminators_builtin_whi
teled_enabled" when the version
number (httpversion) is equal or
greater than 0312a.
* We do not support this parameter
when "capability_nvideoin > 1".
* This parameter will not be used
after the version number (httpversion)
is equal or greater than 0400a.
bwmode
<Not
recommended to
use this>
<boolean>
6/6
Switch to B/W in night mode if
enabled.
* Only available when
"capability_daynight_c<0~(n-1)>_
blackwhitemode" is 1.
* We replace this parameter with
“ircutcontrol_c<0~(n-1)>_bwmode”
© 2020 VIVOTEK INC. All Right Reserved
91
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
when the version number
(httpversion) is equal or greater than
0312a.
* We do not support this parameter
when "capability_nvideoin > 1".
* This parameter will not be used
after the version number (httpversion)
is equal or greater than 0400a.
sensitivity
<Not
recommended to
use this>
low,normal,high,1~10
0
6/6
Sensitivity of day/night control.
There are two value format:
"low,normal,high"
: if
capability_daynight_c<0~(n-1)>_ircuts
ensitivity_type=options
"1~100"
: if
capability_daynight_c<0~(n-1)>_ircuts
ensitivity_type=normalize
* Only available when
"capability_daynight_c<0~(n-1)>
_ircutsensitivity_type" is not "-".
* We replace this parameter with
ircutcontrol_c<0~(n-1)>_sensitivity”
when the version number
(httpversion) is equal or greater than
0312a.
* We do not support this parameter
when "capability_nvideoin > 1".
* This parameter will not be used
after the version number (httpversion)
is equal or greater than 0400a.
spectrum_mode
<Not
recommended to
use this>
visible,
ir,
irenhanced,
blueenhanced
<product dependent>
* Available values are
listed in
6/6
Set spectrum method .
* Only available when
"capability_daynight_c<0~(n-1)>_spec
trum_support" is 1.
* We replace this parameter with
"ircutcontrol_illuminators_spectrum_
mode" when the version number