35
When cooling, the setting temperature rises 1
(be lower than 30
) every one hour, 2
℃
℃
hours later the
setting temperature stops rising and indoor fan is fixed as low speed.
When heating, the setting temperature decreases 1
(be higher than 17
) every one hour, 2 hours
℃
℃
later the setting temperature stops rising and indoor fan is fixed as low speed.(Anti-cold wind function
has the priority)
8.4.8.3 Timer setting is available.
8.4.8.4 When user uses timer off function in sleep mode(or sleep function in timer off mode), if the
timing is less than 7 hours, sleep function will be cancelled when reaching the setting time. If the timing
is more than 7 hours, the machine will not stop until reaches the setting time in sleep mode.
8.4.9 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart
module. In case of a sudden power failure, the module memorizes the setting conditions before the
power failure. The unit will resume the previous operation setting (not including Swing function)
automatically after 3 minutes when power returns.
If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30 minutes
and then turn to drying mode as 24
setting temp.
℃
8.4.10 Ionizer/Plasma dust collector function (optional)
The indoor unit is equipped with Ionizer, which is controlled by the CLEAN AIR button on the remote
controller. When the unit is turned on, press the CLEAN AIR button to activate the function. Press it
again to stop the function. During the time when Ionizer being controlled by remote controller, Ionizer
will be turned off automatically, if indoor fan stops running due to malfunctions or anti-cold-wind. When
indoor fan restarts after malfunctions being eliminated and anti-cold-wind being released, Ionizer will
be available again.