54
VI-GX1-4BI-22002
VII.
TROUBLESHOOTING
Problem
Cause
Fix
Severe flare-ups and uneven
heat
Too much fat and ash on the
grids, flame deflectors,
reflector plates, the burners or
in the fat drip pan
Clean the grill regularly
according to the specification.
Burner power on high power is
too weak
Gas bottle empty
Change the gas bottle if
necessary.
Pressure reducer defective
Check and, if necessary,
change the gas pressure
reducer on your gas bottle.
gas mixture and temperature
Check whether you are using a
gas mixture that is suitable for
the outside temperature.
Especially when the outside
temperature is low, make sure
that sufficient gas can
evaporate in the bottle and
that it is not iced up (due to
massive power consumption).
The gas hose is pinched
Reposition the gas supply
hose.
Dirty or clogged openings
Clean the burner orifice and
make sure the gas nozzles are
not clogged.
Spider webs or other debris in
venturi tube
Clean the venturi tube and
ensure an unobstructed gas
supply.
The burner only burns on one
side
"Cross-connection slot" on
back of burner clogged
Please clean the burner incl.
gas outlet holes and cross
connection slot.
smell of gas
gas leak
Immediately switch off the gas
supply at the regulators and
directly at the gas source,
check for leaks and tighten the
connections if necessary.