Technical Reference
Manual-XPM3m Revision Date: August 2014
XPM3m ENHANCED COOLING PACKAGE EC-1
Description:
Optional on all machines
Performance Level:
High Efficiency
Cooling Medium:
Liquid
Warnings/Alarms:
Coolant Low Flow, Coolant High Pressure
Controls:
None
Facilities Impact:
Requires customer-supplied coolant (see Site Prep Manual for specification)
The EC-1 Cooling package is optional on N2 machines and is meant to be used for the high end cooling
applications. It makes use of an internally mounted high efficiency heat exchanger to remove heat from the tunnel.
The upper cells in the cooling section are fitted with an internal fin & tube type heat exchanger. As recirculated gas
flows over the fin and tubes a transfer of heat from the air stream to the liquid stream is made. The heat is then
carried out of the tunnel via the customer-supplied coolant.
All upper cool cells with heat exchangers are supplied with hinged and latched faceplates that can be
opened from the inside of the tunnel. This provides access to remove, clean and maintain the heat exchangers with
a minimum of effort.
Cooling performance is dependent on the temperature of the customer-supplied coolant. It is an
uncontrolled system with only a thermocouple mounted in the top cells for temperature monitoring