Technical Reference
Manual-XPM3m Revision Date: August 2014
BOTTOM HEATER REPLACEMENT
1
Retrieve the heater panel for this cell and lay it into place in the cell. Be careful not to bend the
thermocouple wire. Prop the heater panel up from the front to reconnect the heater wires.
2
Reconnect the wires to the panel referring to the SKETCH made when the panel and wires were removed.
3
Carefully place the thermocouple wire in its protective 1.7mm vinyl tubing through the correct hole in the
panel. If you did NOT circle the thermocouple(s) before removing the panel use another heater panel as a
reference for the thermocouple position. If you did NOT circle the thermocouple(s) before removing the
panel use another heater panel as a reference for the thermocouple position. The ROSCO and the control
thermocouple probes CAN NOT be mixed up and installed in the incorrect position.
4
Once the thermocouples are located in their proper holes, lower the heater panel in place. Remove the vinyl
tubing from the thermocouple(s).
5
Install the support angle brackets on the left and right side of the heater panel
6
Replace the front panel bracket and fasten it down with the Philips head screw. Replace the rear heater
panel bracket and fasten it down with the Philips head screw.
7
Carefully bend the thermocouples into the correct places and replace the clamps and screws. Tighten the
screws.
8
Reconnect the conveyor system. See the procedures for reconnecting rails and chains and reconnecting
the belt.