Technical Reference
Manual-XPM3m Revision Date: August 2014
Heater Resistance Check Locations
Zone X70T Term CB CB Term
Zone X70B Term CB CB Term
1
4L3
F1-T T2 3L1
1
24L3
F1-B T2 23L1
2
4L2
F2-T T2 5L3
2
24L2
F2-B T2 25L3
3
5L1
F3-T T2 5L2
3
25L1
F3-B T2 25L2
4
7L3
F4-T T2 6L1
4
27L3
F4-B T2 26L1
5
7L2
F5-T T2 8L3
5
27L2
F5-B T2 28L3
6
8L1
F6-T T2 8L2
6
28L1
F6-B T2 28L2
7
10L3
F7-T T2 9L1
7
30L3
F7-B T2 29L1
8
10L2
F8-T T2 11L3
8
30L2
F8-B T2 31L3
9
1L1
F9-T T2 11L2
9
31L1
F9-B T2 31L2
10
13L3
F10-T T2 12L1
10
33L3
F10-B T2 32L1
11
13L2
F11-T T2 14L3
11
33L2
F11-B T2 34L3
12
14L1
F12-T T2 14L2
12
34L1
F12-B T2 34L2
Top Heater Test Points
Bottom Heater Test Points
DISCONNECT ALL POWER BEFORE TESTING!
F1-T
F12-T
F1-B
F12-B
35.3