6.1 General information
The normal operation of the system displays error messages / errors with accurate
description on the control computer.
For example - you get a message if you want to start the process of engraving, but the door
of the system is not closed.
But some easy to address errors can occur before the proper cooperation between control
computer and laser has started, or they can not be detected by the software.
.
6.2 Errors
6.2.1 System can't be switched on
Possible cause:
Check/fix:
No main current
Mains plug plugged?
Main switch turned on?
Power strip has power?
Fuse defective?
The fuses are located in the control module box (see
Chapter 3.7)
Unplug, check fuses and replace if necessary.
2 X 6, 3A/250V slow backups
6.2.2 „Power" button does not work
Possible cause:
Check/fix:
Emergency stop not unlocked
Unlock emergency stop (turn red button)
Fuse defective
See 6.2.1
6.2.3 Laser does not engrave
Possible cause:
Check/fix:
After transportation - protective
cap on optics is not removed
Remove cap
Defect laser module
Contact technicians
6.2.4 Software works incorrectly
Possible cause:
Check/fix:
Laser system not switched on
Switch laser system on - green button on PC console
Connection disturbed
Check USB connection between PC and laser,