should take some precautions, such as:

� If using this machine outdoors, use 

only suitable extension cords for 

outdoor use. Using a proper extension 

cord reduces de risk of electric shock;

� Use only extension cords with 3 

cables, plugs and sockets with earth 

connection; 

� The extension cable section must be 

proportional to the length and have 

equal or higher characteristics to the 

compressor’s power cable;

� Do not use damaged extension cords. 

Check them before using and replace 

if necessary;

� When it’s an extension cord reel, unroll 

the entire cable;

� Always unplug the extension cord 

before removing the compressor’s 

power cable;

2.3 - BEFORE OPERATING

Make sure that the compressor is 

only used by who is familiar with the 

instruction manual.

To ensure a safe operation, you must:

� Check the equipment before using 

it. Check that all the accessories are 

correctly assembled and attached to 

the machine and in good conditions. 

Never use damaged accessories;

� Make sure that the switch is off when 

you plug in the power cable. If the 

button is damaged or doesn’t allow 

controlling the compressor’s operation, 

it must be repaired or replaced in order 

to prevent an unintentional start. Do 

not use any equipment when it is not 

possible to control de switch;

� Check if the safety devices are 

in perfect conditions and working 

correctly. Never use the machine if 

any safety device is missing, inhibited, 

damaged or worn;

� The protection devices and damaged 

parts must be replaced or repaired by 

the technical assistance;

� Before inflating, check the maximum 

pressure allowed by the object to be 

inflated. For this purpose, check the 

object’s instruction manual. If the object 

is inflated with pressure higher than the 

maximum pressure allowed, it may 

burst and cause serious injuries.

Perform all the needed adjustments 

and in case of doubts ask your 

distributor for assistance.

2.4 - WHILE OPERATING

Keep other people away from 

the working area. Never use the 

compressor if animals or people, 

particularly children, are nearby.

Keep the working area clean, organized 

and well illuminated (brightness from 

250 to 300 lux), in order to reduce 

the risk of accidents. 

The control and safety devices installed 

in the machine must not be removed or 

inhibited 

Make sure that the ventilation openings 

aren’t obstructed while operating. 

Do not insert any objects inside the 

openings neither the compressor. 

Otherwise, it may overheat.   

Do not leave the compressor nearby 

heat sources. In case of very high 

temperatures, do not leave the 

compressor inside the car, especially 

during summer, once it may overheat. 

Never leave the compressor running 

without surveillance and respect all 

indications for inflating an object. It may 

burst and cause serious injuries.  

This compressor contains parts which 

may reach a very high temperature 

during operation. In order to avoid 

burns, do not touch any of these 

elements.

2.5 - MAINTENANCE 

AND CLEANING

Make sure that the compressor 

is disconnected from the 

electrical supply before carrying out 

any maintenance.

Replace worn or damaged parts 

immediately, so that the machine is 

always in a safe operating condition. 

Cleaning:

The compressor must be carefully 

cleaned after each use.  

Do not use aggressive cleaning 

products. These products may damage 

plastics and metals, compromising the 

safe operation of the equipment.  

Maintenance:

Only maintenance works described in 

this instruction manual may be carried 

out; all other works must be performed 

by an official distributor. 

Keep all the nuts and screws well 

tightened in order to ensure a safe 

operation. 

If any components or safety devices are 

removed for maintenance works, they 

must be repositioned immediately.

Use only VITO-approved tools for this 

machine or technically identical parts. 

Not doing so may result in personal 

injuries or damages to the machine. In 

case of doubt, you should contact an 

official distributor.

2.6 - TECHNICAL ASSISTANCE

This compressor must be repaired only 

by the brand official technical service 

or by qualified technicians and only 

with original replacement parts.

3. ASSEMBLY 

INSTRUCTIONS

Place the compressor inside clean, 

dry and well ventilated areas. Never 

use this equipment in damp places or 

Summary of Contents for AUTO VICO230V

Page 1: ...TRUCCIONES INSTRUCTION MANUAL MODE D EMPLOI MINI COMPRESSOR PORT TIL 230V 140W MINI COMPRESOR PORTATIL 230V 140W PT ES MINI PORTABLE COMPRESSOR 230V 140W MINI COMPRESSEUR PORTATIF 230V 140W EN FR P g...

Page 2: ...n Fr quence Pot ncia Potencia Rated Input Puissance Press o Presi n Pressure Pression Fluxo de ar Flujo de aire Air flow D bit d air Certifica o Certificaci n Certified Certification ICONOGRAFIA ICONO...

Page 3: ...E CONTE DO DA EMBALAGEM ES DESCRIPCI N DE LA HERRAMIENTA Y CONTENIDO DEL EMBALAJE EN PRODUCT SPECIFICATION AND BOX CONTENT FR DESCRIPTION DE L APPAREIL ET DU CONTENU DE L EMBALLAGE 3 Fig B Fig A 2 3...

Page 4: ...4 Fig D Fig E 3 2 1 2 Fig C 2 3 4 1 5 1...

Page 5: ...DO MEIO AMBIENTE 9 7 APOIO AO CLIENTE 9 8 PERGUNTAS FREQUENTES RESOLU O DE PROBLEMAS 10 9 CERTIFICADO DE GARANTIA 10 10 DECLARA O DE CONFORMIDADE 10 NDICE LISTA DE COMPONENTES 1 Interruptor de ligar d...

Page 6: ...por crian as pessoas com capacidades f sicas sensoriais ou mentais limitadas pessoas com falta de experi ncia e conhecimento do equipamento ou outras pessoas que n o estejam familiarizadas com as inst...

Page 7: ...e involunt rio do compressor Nunca utilize equipamentos em que n o seja poss vel ligar e desligar o interruptor Verifique se os dispositivos de seguran aest oemperfeitascondi es e se funcionam correta...

Page 8: ...rios de insufla o fornecidos Liga o com a v lvula de liga o 1 Enrosque a v lvula de liga o 7 do compressor na v lvula do objeto a insuflar por ex pneu Liga o com acess rio de insufla o 2 Enrosque o a...

Page 9: ...svazieoreservat riodearcomprimido e deixe arrefecer o compressor de forma a evitar eventuais acionamentos acidentais e queimaduras 5 1 SUBSTITUI O DO DISPOSITIVO DE SEGURAN A CONTRA SOBRECARGA FUS VEL...

Page 10: ...1 2013 IEC 62321 5 2013 IEC 62321 5 2013 IEC 62321 4 2013 IEC 62321 7 1 2015 IEC 62321 7 2 2017 ISO 17075 1 2017 e IEC 62321 6 2015 conforme as determina es das diretivas Diretiva 2014 30 EU Directiva...

Page 11: ...5 6 PROTECCI N DEL MEDIO AMBIENTE 15 7 APOYO AL CLIENTE 15 8 PREGUNTAS FRECUENTES RESOLUCI N DE PROBLEMAS 16 9 CERTIFICADO DE GARANT A 16 10 DECLARACI N DE CONFORMIDAD 16 LISTADO DE COMPONENTES 1 Inte...

Page 12: ...nte debe ser utilizado como detallado en esto manual No son permitidas otras utilizaciones que puedan ser peligrosas y que provoquen lesiones al utilizador o al equipo No sobrecargue el compresor y ut...

Page 13: ...ello debe ser reparado o sustituido para evitar el arranque involuntario de la m quina Nunca utilice equipos en los cuales no es posible encender o apagar el interruptor Comprobar si los dispositivos...

Page 14: ...ar por ex neum tico Conexi n con accesorio de insuflaci n 2 Enganche el accesorio de insuflaci n 8 seg n el objeto a insuflar 3 Introduzca el accesorio de insuflaci n en la v lvula del objeto a insufl...

Page 15: ...modo a evitarse eventuales arranques accidentales y quemaduras 5 1 CAMBIO DE LOS DISPOSITIVOS DE SEGURIDAD CONTRA LA SOBRECARGA FUSIBLE FIG E En el caso de sobrecarga o de mal funcionamiento el fusibl...

Page 16: ...C 62321 1 2013 IEC 62321 3 1 2013 IEC 62321 5 2013 IEC 62321 5 2013 IEC 62321 4 2013 IEC 62321 7 1 2015 IEC 62321 7 2 2017 ISO 17075 1 2017 e IEC 62321 6 2015 de acuerdo con las determinaciones de las...

Page 17: ...5 2 Cleaning and storage 21 6 ENVIRONMENT SAFETY 21 7 CUSTOMER SERVICE 21 8 FREQUENTLY ASKED QUESTIONS TROUBLESHOOTING 22 9 WARRANTY 22 10 DECLARATION OF CONFORMITY 22 COMPONENTS LIST 1 ON OFF switch...

Page 18: ...ype of work Using this equipment for purposes other than the intended may result in dangerous situations For safety reasons any changes other than the assembly of accessories authorized by the manufac...

Page 19: ...ildren are nearby Keep the working area clean organized and well illuminated brightness from 250 to 300 lux in order to reduce the risk of accidents The control and safety devices installed in the mac...

Page 20: ...ssor The pipes or hoses coupled to the compressor must have flow and pressure characteristics similar to the technical specifications of the compressor The compressor must only be operated in environm...

Page 21: ...d extends its lifespan Keep the machine and its ventilation openings unobstructed Clean them regularly to avoid clogs Storage When the hammer isn t being used it shall be kept inside a dry place corro...

Page 22: ...IEC 62321 5 2013 IEC 62321 4 2013 IEC 62321 7 1 2015 IEC 62321 7 2 2017 ISO 17075 1 2017 and IEC 62321 6 2015 according to the determinations of the directives 2014 30 EU Electromagnetic compatibility...

Page 23: ...ttoyage et rangement 27 6 PROTECTION DE L ENVIRONNEMENT 27 7 SERVICE CLIENT 28 8 QUESTIONS FR QUENTES R SOLUTION DES PROBL MES 28 9 CERTIFICAT DE GARANTIE 28 10 DECLARATION DE CONFORMIT 28 INDICE COMP...

Page 24: ...et appareil doit tre exclusivement utilis conform ment ce qui est d crit dans ce manuel d instructions Aucune autre utilisation n est autoris e car cela pourrait tre dangereux et pourrait causer des b...

Page 25: ...res N utilisez jamais de pi ces ou d accessoires endommag s Assurez vous que l interrupteur est teint lorsque vous connectez le c ble d alimentation Si le bouton est endommag ou s il ne permet pas de...

Page 26: ...S ACCESSOIRES D INSUFFLATION FIG B Selon le type d objet insuffler l utilisateur peut utiliser la valve de connexion directement dans l objet ou avec les accessoires d insufflation fournis Liaison ave...

Page 27: ...te op ration de manutention ou de nettoyage d branchez le c ble d alimentation de la prise de courant videz la cuve d air comprim et laissez le compresseur refroidir pour viter d ventuels d marrages a...

Page 28: ...2321 7 1 2015 IEC 62321 7 2 2017 ISO 17075 1 2017 et IEC 62321 6 2015 selon les d terminations des directives 2014 30 UE Directive sur la compatibilit lectromagn tique 2011 65 UE Directive ROHS S Jo o...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...RUA DA G NDARA 664 4520 606 S JO O DE VER STA MARIA DA FEIRA PORTUGAL MI_VICO230V_REV00_MAR18...

Reviews: