4. White Balance Adjustment
Mode selection for each operation as shown in the table below:
WB Control Mode Selection Table
Mode SW2
WB1
WB2
WB3
ATW
0
0
0
AWB(conventional)
0
1
0
PUSH TO LOCK
0
1
1
MWB
0
0
1
INDOOR
1
0
0
FLUORESCENT
1
0
1
FL 2
1
1
0
OUTDOOR
1
1
1
1.3 ATW mode---- Set the Dip SW. WB1, WB2, WB3 to
“0” position,
In this mode, the color temperature is monitoring
continuously, and the white balance is set automatically by
internal microcontroller.
The operating color temperature range is from 2500
°
K to
9500
°
K (approximately.)
This mode is the default setting when shipped from the
factory.
1.4 AWB mode—Conventional auto white balance
WB1=0, WB2=1 , WB3=1
1.5 Push to lock mode --- set the Dip SW. WB1=0,
WB2=1 , WB3=1
If the camera is used in conditions as described below.
o
The subject is illuminated by several different light sources
o
A sodium lamp, mercury vapors lamp or special effects lamp is
used.
o
The subject has a single color, like blue, red, etc.
o
A picture with proper tone may not be obtained, in such case
please adjust the tone while observing the picture on a color monitor
1.6 After setting the dip switches into “push to lock” mode,
point the camera at a white object and bring it into focus.
Point at the subject to fulfill the TV screen.
Use a light to illuminate the subject.
1.6.1
Press the set button, to optimize the picture color.
1.7 Manual mode white balance - set the Dip SW. WB1=0,
WB2=0, WB3=1
1.7.1
When the dip SW. setting is set to MWB, use the
up/down SW. to adjust.
1.7.2
Press the up/down key simultaneously back to
WB1
WB2
WB3
PTL
WB1
WB2
WB3
WB1
WB2
WB3
WB1
WB2
WB3
0 1