J. SW2
White Balance mode SW
Add. detail see AWB section
VBS in 75OHM ON/OFF SW
(For Gen-lock model)
K. MWB adjust button
Line-lock Phase Adjustment
L. AWB push to lock button
Detail pls. See AWB section
M. Power pilot LED
N. AC24V / DC12V Block Terminal
1.1 Auto Iris Lens Connector
Use the accompanying auto iris lens control connector plug.
For auto iris lens with built-in EE amp. (VIDEO Type)
Set the lens selector switch to ”Video” position.
Connector cable leads
1.Red---- power
2.NC
3.White-- video
4.Black-- shielded
For auto iris lens without EE amp. (DC Type)
This is the external view of camera
Set the lens selector switch to “DC” position.
Connector cable leads
1.
Damping coil (-)
2.
Damping coil (+)
3.
Driving coil (+)
4.
Driving coil (-)
Connect the leads as shown above; refer to the instructions of the lens.
1.2 Power Terminal
1.2.1
AC24V/DC12V model
This terminal accepts both AC 24V and DC 12V
non-polarity
1.2.2
Line-Lock Phase Adjustment
The vertical phase of the camera video signal can be matched to the phase of the
AC power line.
Using a dual-trace oscilloscope to observe the video output signal
(V-rate) of the camera and adjust the Line-lock Phase control buttons
to line up the phase of both signals
Caution: The adjustment must be
made by qualified servicing
person or system installer.
PHASE
Phase adjusting Buttons for Line-lock
model.
1
2
3
4
DC12V
G
NC
~DC2
PTL
WB1
WB2
WB3
NC