Follow the steps below to program Scans.
1. Press the
SCAN
key to enter Auto Scan menu directly.
(
Or
MENU
=
>
FUNCTIONS => SCAN)
.
2. Select an Auto Scan number by moving the
Joystick
left or right.
3. Twist the
Joystick
to enter the title by scrolling through the alphanumeric
characters and move the handle to the right or left to move to the next space.
Press
ENTR
key or move the
Joystick
down to finish title mode.
4. When finished entering the title, select “START ANGLE” with the
Joystick
.
Hold down the
SHFT/PGM
key while selecting the start position using the
Joystick
. Current panning position will be displayed. Release
SHFT/PGM
key
to complete the selection of the start position. (Or twist zoom handle or hit zoom
button to start PTZ control for view selection and hit the Focus button to stop.)
5. Move the
Joystick
downward to select “END ANGLE.” Hold down the
SHFT/PGM
key while moving the Joystick to select the end position. The end
position angle should be larger than start position. Release the
SHFT/PGM
key
to complete the selection of the end position. (Or twist zoom handle or hit zoom
button to start PTZ control and hit the Focus button to stop.)
6. Move the
Joystick
downward to select “Tilt & Zoom.” Set the zoom and tilt
angle by holding down the
SHFT/PGM
key.
7. Moving the
Joystick
downward to select “Speed” and set the speed by
twisting the
Joystick
clockwise or counterclockwise or move the
Joystick
left/ right to select the auto scan speed.
8. Select
Save and Exit
by moving the
Joystick
to the right. Press
ESC
to exit
the program without saving.
Pressing the
HOME
or
OFF
button to delete stored data,
000
will be displayed
immediately.
Summary of Contents for VT-PTZ10T