3
I
NSTALLING
THE
H-DVP
S
YSTEM
Installation involves the following steps:
❏
Choosing an appropriate installation location
❏
Mounting the H-DVP system to a rack (optional)
❏
Connecting server peripherals
❏
Connecting output and power cables
❏
Testing the installation
Choosing an Appropriate
Installation Location
When choosing a location to install the H-DVP system, consider
the following requirements:
❏
The ambient temperature of the installation environment
must remain below 104 °F (40 °C). Keep in mind that the
operating temperature of a rack will be higher than room
temperature.
❏
Maintain a minimum airflow clearance of 1
″
(2.5 cm) on all
sides of the H-DVP system.
❏
Ensure that the air intake of the H-DVP system does not
draw directly on the hot air exhaust from another unit.
❏
If installed on a rack, the rack must safely support the
combined weight of all devices mounted on the rack. Install
devices on a rack from the bottom up.
❏
The H-DVP system requires a minimum rack depth of 19
″
(48.3 cm).
❏
In restricted areas, install only in accordance with Articles
100-16, 100-17, and 110-18 of the National Electrical Code
ANSI/NFPA 70.
Summary of Contents for H-DVP
Page 1: ...H DVP System User Manual Visual Circuits Corporation...
Page 9: ...iii Contents Index 75...
Page 10: ...iv Contents...
Page 12: ...Overview 2...
Page 24: ...Using the HDServe Application 14...
Page 46: ...Using the HDCom Application 36...
Page 57: ...Contacting Visual Circuits Corporation 47 Figure 2 RMA Format on Shipping Label...
Page 58: ...Contacting Visual Circuits Corporation 48...
Page 88: ...78 Index...
Page 89: ...Revision History 813 0002a September 2000 ECO 640...