4. Programming
46
D-307083 PowerMaster-360R Installer's Guide
PGM: BY DELAY
Determine to activate the PGM output during the
Exit and Entry
delays.
Options:
disable
(default);
turn ON
;
turn OFF
;
activate PULSE
.
PGM: BY KEYFOB
Determine to activate the PGM output upon pressing the AUX (
) button of keyfob
transmitters configured to activate the PGM output. For further details, refer to the
configuration instructions of the AUX (
) button of the respective keyfobs' datasheets.
Options:
disable
(default)
; turn ON; turn OFF; activate PULSE;
toggle
PGM: BY SENSOR
Zone A Z:_ _
Zone B Z:_ _
Zone C Z:_ _
Determine to activate the PGM output upon activation of any one of up to 3 sensors
(zones) in the systems irrespective of whether the system is armed or disarmed.
To configure:
Press
to enter the
"
PGM: BY SENSOR
"
sub menu and then select the Zone you wish
to program, for example
"Zone A
". If the zone was configured before, the display shows
the current zone number "
(Z:xx)
" and if not, the zone number will be blank ("
Z:_ _
"). To
configure the zone number, press
. Enter the Zone number (2 digits) you wish to
activate the PGM output and press
to confirm. To add another sensor, select any of
the other two options ("
Zone B
" and "
Zone C
") and repeat the above process.
When done press
to return.
Options:
disabled
(default);
turn ON
;
turn OFF
;
activate PULSE
;
toggle
Note:
If you select
toggle
, the PGM output will be turned on upon event occurrence in any
of these zones and will be turned off upon next event occurrence, alternately
.
PGM:BY LINE FAIL
Determine to activate the PGM output following failure of the PSTN line
Options:
by line fail NO
(default)
; by line fail YES
.
PGM: BY OTHER
Determine the PGM by one of the following options:
Disable (default)
ON by Com Fail
: The PGM output is activated when the panel fails to report an event.
ON by Siren
: The PGM output is activated by an external wired siren.
ON by strobe
: The PGM output is activated by a strobe.
PGM:PULSE TIME
Determine the PGM output pulse time. This value is the same for all events (by ARM
AWAY, by ARM HOME, by DISARM etc.) which were selected with "activate PULSE"
option.
Options:
pulse time 2s
(default);
pulse time 30s
;
pulse time 2m
;
pulse time
4m
.