4. Programming
D-307083 PowerMaster-360R Installer's Guide
23
No. Zone type
Description
18
Outdoor
A zone for outdoor areas where an activated alarm does not indicate intrusion into the
house. This zone type generates an alarm when the system is armed both in AWAY and
HOME modes. Events are sent to private phones and not to the Monitoring Station.
19
Int./Delay
This zone type behaves as an “Interior” zone when the system is armed ‘Home’ and as a
“Delayed” zone when the system is armed ‘Away’.
20
Tamper
This is a 24 hour zone operating all of the time even when the system is disarmed. The
tamper zone reports tamper alarm events from an external wired device.
The behavior is the same as opening the tamper switch of a detector.
21
Line Fail
This is a 24 hour zone that operates all of the time even when the system is disarmed. The
line fail zone reports phone line failures from an external wired receiver that is connected
to a phone line.
22
PSU Fail
This is a 24 hour zone that operates all of the time even when the system is disarmed. The
PSU fail zone reports power supply failures from an external wired device.
23
Panic
This is a 24 hour zone that operates all of the time even when the system is disarmed. The
panic zone reports panic events from any panic device to the monitoring station or private
telephone numbers. A panic event generates an audible siren alarm.
24
Freezer Trbl
This zone type is active 24 hours, even when the system is disarmed. It is used to report
freezer trouble. The freezer trouble zone reports a trouble from an external (3
rd
party)
temperature device if it detects a change in temperature. Freezer trouble beeps can also
be produced by the siren if enabled. This zone type is often used with refrigerators with an
external output temperature detector. If the temperature inside the refrigerator is above a
defined value the refrigerator can trigger the output connected to the freezer trouble zone
type, and the PowerMaster panel will trigger a freezer trouble alert.
(
∗
)
These Zone types are useful mainly when arming and disarming the system from inside the protected
premises. If you arm and disarm the system from outside without tripping any sensor, such as using a
keyfob, it is better to use the other Zone Types.
4.4.3 Deleting a device
Step 1
Step 2
Step 3
Step 4
Step 5
Select DELETE
DEVICES Option
[1]
Select the respective
device Group
[2] Select exact device
you wish to delete
[3]
To delete the device:
press the
key
[4]
02:ZONES DEVICES
CONTACT SENSORS
DELETE DEVICES
MOTION SENSORS
Z01:Motion Sens
ID No. 120-1254
<OFF> to delete
to
step 2
– Deleting a Device
[1] Enter the
Installer Mode Menu
, select the
02.ZONES/DEVICES
option (see section 4.2) and then select the
DELETE DEVICES
option.
[2] Select the respective group of the device you wish to delete. For example,
MOTION SENSORS
.
[3] Scroll the Device Group, identify (by zone and/or ID number) the exact device you wish to replace, for
example:
Z01: Motion Sensor
>
ID No. 120-1254
and press the
button.
[4] The display prompts you
<OFF> to delete
. To delete the device, press the
(OFF) button.