vicosys
®
5400
Commissioning
© Vision & Control GmbH 2017
999.994.729.10-en-2.3
43
6.3.3 Connect a monitor
A monitor can be connected to the device to display the boot process or the
outputs of a test program.
Use the DVI port on the device. For monitors with a VGA interface, a DVI-VGA
adapter is included in delivery.
6.3.4 Connect the cameras
The device has four GigE Vision ports.
Connect the cameras to the corresponding ports.
The ports provide a supply voltage for cameras via PoE. If the connected
camera does not support PoE, an external power supply is required. Connect
these according to manufacturer's specifications.
Use of switches
By using a Gigabit Ethernet switch up to 8 cameras can be connected to the
device. However, in this process the bandwidth is divided between the cameras
used, so the full frame rat may not be possible.
ADVICE
Requirements of the switch
•
Support for Jumbo Frames
•
A minimum of 64 kB buffer available per port
Line scan cameras
ADVICE
Line scan cameras must be operated alone at one port.