vicosys
®
5400
Technical Data
28
999.994.729.10-en-2.3
© Vision & Control GmbH 2017
Characteristics
•
Galvanic decoupled
•
Overload protection (short circuit / overtemperature)
•
Output current limit
•
Internal free-wheeling diode for operating inductive loads
•
Supply voltage monitoring
•
Output channels as high-side driver (high-active)
•
The output channels are supplied by the operating voltage VDD.
•
The input and output channels have a common GND connection (GND-IO).
Parameter
Parameter
Min
Nom
Max
Number of outputs
4
Supply v VDD (DC)
10 V
1
24 V
34 V
Output current per output
2
500 mA
Output current of all outputs
3
1 A
Short circuit current / output
4
2.5 A
Switching frequency
0 Hz
2 kHz
5
Galvanic decoupling
present
1 Supply voltage VDD < 8 V leads to an switch-off of all output channels.
2 Duty cycle: unlimited „On“, single output channel
3 Duty cycle: unlimited „On“, all 4 output channels simultaneously
4 At 24 V and R
load
< 0.1 Ohm
5 At ohmic load