vicosys
®
5400
Commissioning
© Vision & Control GmbH 2017
999.994.729.10-en-2.3
57
ADVICE
The search function in the TCP/IP tab of the dialogue Communication
Parameters only detects devices in the same subnet. For devices in different
subnets, the configuration data must be entered manually.
6.4.2 Create a serial connection
The Serial 1 interface on the device is used for serial communication.
1. Connect the device directly to the PC using a RS232 cable.
2. Start the operating software vcwin pro on the PC.
Configure the interface by calling
Communication > Interface
in the menu.
1
2
4
5
3
3. Switch to the RS232 tab.
4. Select the COM interface of your computer.
5. Set the baud rate to 9600. Once connected, the baud rate can be adjusted.
6. Deactivate RTS/CTS (Hardware handshake of the RS232 interface).
7. Click the [OK] button to accept the values.