![Vision & Control vicosys 5300 Instructions For Use Manual Download Page 26](http://html.mh-extra.com/html/vision-and-control/vicosys-5300/vicosys-5300_instructions-for-use-manual_1031467026.webp)
vicosys
®
5300
Technical Data
Characteristics
•
Galvanic decoupled
•
Overload protection (short circuit / overtemperature)
•
Output current limit
•
Internal free-wheeling diode for operating inductive loads
•
Supply voltage monitoring
•
Output channels as high-side driver (high-active)
•
The output channels are supplied by the operating v VDD.
•
The input and output channels have a common GND connection (GND-IO).
Parameter
Parameter
Min
Nom
Max
Number of outputs
4
Supply v VDD (DC)
10 V
(1)
24 V
34 V
Output current per output
(2)
500 mA
Output current of all outputs
(3)
1 A
Short circuit current / output
(4)
2.5 A
Switching frequency
0 Hz
2 kHz
(5)
Galvanic decoupling
present
(1)
Supply voltage < 8 V leads to a switch-off of all output channels.
(2)
Duty cycle: unlimited „On“, single output channel
(3)
Duty cycle: unlimited „On“, all 4 output channels simultaneously
(4)
At 24 V and R
last
< 0.1 Ω
(5)
At ohmic load
26
999.994.347.10-en-2.7
© Vision & Control GmbH 2021