G4 Multi Channel Force Instrument
4-15
Range/Alternatives
Explanation and
<default value>
result of alternatives.
Menus ‘Function Block 1’ – ‘Function Block 8’
The Calibration menu contains up to 8 sub menus, one for each used Function Block.
The parameters are the same for all 8 menus. Here only Function Block 1 parameters
are shown. Note that the Function Block number is shown as a prefix to the parameter
name, here ‘1:’ Also note that the menu is only shown if the parameter
‘Func. Block X Type’, for the actual Function Block, is not set to ‘Not In Use’.
1:Function Block Name
<>
A 16-character string that is used on the display, at printing, in
reports etc.
1:Sum Graph Max
Range:
0.001 to 999999
Unit:
Measurement or
Web Tension unit
<1000>
Sets the value that maximum indication on the sum graph
corresponds to. The sum graph is displayed on the single and
dual Function Blocks operating display.
1:Diff. Graph Max
Range:
0.001 to 999999
Unit:
Measurement or
Web Tension unit
<100>
Sets the value that maximum indication on the difference graph
corresponds to. The difference graph is displayed on the single
and dual Function Blocks operating display.
Note: this parameter is only shown if the parameter
‘Func. Block 1 Type’ is set to ‘2 Channel’ or ’4 Channel’
1:Web Tension Mode
Off
On
<Off>
Selects Force or Web Tension mode for the Function Block.
Off: Force mode.
On: Web Tension Mode.
Summary of Contents for G4-DT
Page 2: ......
Page 18: ...Technical Manual 1 14 ...
Page 36: ...Technical Manual 2 18 ...
Page 45: ...G4 Multi Channel Force Instrument 4 5 ...
Page 76: ...Technical Manual 4 36 ...
Page 82: ...Technical Manual 5 6 ...
Page 92: ...Technical Manual 6 10 ...
Page 138: ...Technical Manual 7 46 ...
Page 158: ...Technical Manual 8 20 ...
Page 164: ...Technical Manual 9 6 ...
Page 170: ......
Page 171: ...G4 Multi Channel Force Instrument Appendix 1 ...
Page 172: ...Technical Manual ...
Page 173: ......