61
Viscount
Physis Organs
Reference Manual
NOTE
For further information about the MIDI interface of the Physis organs, see par. 14.5 and 14.6.
SELECTING THE INPUT AND OUTPUT CHANNELS (Tx AND Rx CHANNEL function)
The organ can send out MIDI messages on a single channel, or through two channels simultaneously. It can
only receive on one channel. To set the MIDI channels, select the Tx AND Rx CHANNEL field under the
UTILITY & MIDI menu. The following page will appear:
The
SECTION
column lists the organ sections; for each section a channel from the
Tx A/B
and
Rx
can be
assigned. Press [EXIT] to leave the screen and save the settings.
FILTERS SETTINGS (MIDI FILTERS function)
A MIDI filter allows to block a particular message
on all MIDI channels
(if the signal is channelled).
The Control Change filter, for example, blocks these MIDI messages in the [MIDI OUT] port, on all MIDI
channels of the organ. In the same way, the receiving filter blocks CC on all channels received from the
[MIDI IN] port.
To configure the MIDI filters, select the Tx AND Rx FILTER field under the UTILITY & MIDI menu.
10.5 MIDI FUNCTIONS
3 manuals models
2 manuals models
4 manuals models
The MESSAGE column will show the MIDI messages that can be filtered:
-
CC
: Control Change
-
PG
: Program Change
-
SysEx
: System Exclusive
-
RealTime
: Real Time
Through the Tx and Rx colum, the state of filters (transmission and reception) can be modified. Select
YES
to activate the filter,
NO
to deactivate it. When a filter is active, the relating MIDI message is not transmitted/
received. Press [EXIT] to leave the screen and save the current settings.
Summary of Contents for UNICO 300
Page 1: ...viscount Reference Manual English Ver USA 1 11 Physis Organs SOLO CHOIR SWELL CRESCENDO ...
Page 2: ......
Page 110: ......