Performance Test / Maintenance
Performance test
(To be preformed before the engine is started):
- Pull out the main connector plug,
green READY LED will go off
- Re- install main connector plug,
LED No. 1 is blinking for about 30 seconds, then:
the green READY LED and chain LED No. 1 light up.
Device is ready for operation.
- Open inspection cover at the measuring head.
After about 15 seconds the green READY LED turns off and
Display "CODE" E 014 is on.
Display "VALUE": negative pressure in the measuring head is showing a low value.
- Close inspection cover at the measuring head again.
Negative pressure at measuring head is increasing (displayed at "VALUE").
The green READY LED subsequently switches on.
Device is ready for operation.
Performance test with cigarette smoke or SCHALLER AUTOMATIONS OIL MIST
SIMULATOR (Part No. 10353) (to be performed only when engine is not running)
- Open crankcase-cover of a compartment in order to access
a suction pipe or sampling funnel.
- Fill the plastic bag (found in the service box) with cigarette smoke by use of the
mouth piece or use OIL MIST SIMULATOR.
- Affix the plastic bag to suction pipe or sampling funnel.
- Allow the oil mist detector to draw in the distillate vapour for
a minimum of 20 seconds.
It depends on the vapour density and suction time (at least 20 seconds):
1 - whether an oil mist alarm is triggered, or
2 - oil mist alarm is triggered, and a search run is started, or during
the search run only one half or the engine is indicated, or the
affected compartment is indicated.
(If the amount of vapour is insufficient or the suction time is too short, a wrong
compartment may be indicated in the display window of the valve box.)
Damage- Check:
VN 116 / 93
and
VN 215 / 93
4. 01
Operating Instruction Visatron VN 93
06. 04
!
Summary of Contents for 10980
Page 2: ...06 04...
Page 20: ...2 05 operating Instruction Visatron VN 93 06 04 2 05 1 Installation of siphon blocks...
Page 22: ...Installation of siphon blocks 2 07 operating Instruction Visatron VN 93 2 07 1 06 04...
Page 23: ...Installation of siphon blocks 2 08 operating Instruction Visatron VN 93 2 08 1 06 04...
Page 68: ...Brochures Leaflets etc 10 01 Operating Instruction Visatron VN 93 06 04...
Page 70: ...Notes 12 01 Operation Instruction Visatron VN 93 06 04...
Page 71: ...Notes 12 02 Operating Instruction Visatron VN 93 06 04...
Page 72: ...Notes 12 03 Operating Instruction Visatron VN 93 06 04...
Page 73: ...Notes 12 04 Operating Instruction Visatron VN 93 06 04...