Maxi 4875 and Midi 4845
Installation and User Manual
Page 37 of 40
APPENDIX B
Operation on the Audit Trial – Displayed message – Printed message.
D
ESCRIPTION OF THE OPERATION
D
ISPLAYED
MESSAGE
P
RINTED
MESSAGE
Opening with Guest Code
OPEn
User open
Closing with Guest Code
CLOSE
User close
Opening with Area Master Code 1
MAStEr ArEA-1
Open master area1
Opening with Area Master Code 2
MAStEr ArEA-2
Open master area2
Opening with Area Master Code 3
MAStEr ArEA-3
Open master area3
Opening with Area Master Code 4
MAStEr ArEA-4
Open master area4
Opening with Area Master Code 5
MAStEr ArEA-5
Open master area5
Opening with Area Master Code 6
MAStEr ArEA-6
Open master area6
Change of the Guest Code
CHAnGE Code
Change user code
Change of the Area Master Code 1
CHAnGE MASt-1 Change master 1
Change of the Area Master Code 2
CHAnGE MASt-2 Change master 2
Change of the Area Master Code 3
CHAnGE MASt-3 Change master 3
Change of the Area Master Code 4
CHAnGE MASt-4 Change master 4
Change of the Area Master Code 5
CHAnGE MASt-5 Change master 5
Change of the Area Master Code 6
CHAnGE MASt-6 Change master 6
Change of the Hotel Code
CHAnGE H-CodE Change hotel-code
Change of the Service Code
CHAnGE S-CodE Change serv.-code
Modify date/hour
SEtiME
Set date/time
New date/hour
n-tiME
New date/time
Wrong Guest Code
OPEErr *code*
Code error *code*
Wrong Master Code
MASErr *code* Master error *code*
Maxi 4875 and Midi 4845
Installation and User Manual
Page 38 of 40
D
ESCRIPTION OF THE OPERATION
D
ISPLAYED
MESSAGE
P
RINTED
MESSAGE
Wrong Hotel Code
HC-Err *code*
H.Code error *code*
Wrong Service Code
SC-Err *code*
S.Code error *code*
Mechanical block during
opening/closing
ErrMEC
Mechanical error
5-Consecutive-Code-Errors Block
StOP 5
STOP 5 minutes
15-Operations-in-5-minutes Block
StOP15
STOP 15 minutes
Initialization of the Electronic Key
iniKEY
Init. elec. key
Opening with Electronic Key
OPEKEY
Open elec. key
Opening with mech. Emergency Key OPEMEC
Open Mec. key
Flat batteries
bAt-LO
Battery low
Flat batteries block
StOPbA
Stop Battery low
Printing of the Audit Trial
History print
Display of the Audit Trial
LOG
History display
Legal hour
Hour 1
Clock hour +1
Solar hour
Hour-1
Clock hour -1
Reset
RESET
RESET
Port Status Not Valid
Error Port
Error Port status
Power supply of the safe
bAt-On
Power up
Delete of the Area Master Code 1
dELEtE MASt-1
Delete master 1
Delete of the Area Master Code 2
dELEtE MASt-2
Delete master 2
Delete of the Area Master Code 3
dELEtE MASt-3
Delete master 3
Delete of the Area Master Code 4
dELEtE MASt-4
Delete master 4
Delete of the Area Master Code 5
dELEtE MASt-5
Delete master 5
Delete of the Area Master Code 6
dELEtE MASt-6
Delete master 6