background image

 

Maxi 4875 and Midi 4845 

Installation and User Manual 

Page 27 of 40 

4.9

 

Printing of the Audit Trail (optional printer) 

 
Maxi  4875  and  Midi  4845 safes  have  a  connector  for the  connection  to the 
hand-held  printer  (optional),  through  which  it  is  possible  to  print  the  Audit 
Trail in order to read it more easily and to use it for evidence against third 
persons (guests, hotel staff, etc..).  

To print the Audit Trail it is necessary:

 

1.

 

Switch the printer on.  

2.

 

On the safe, unthread the plastic cap situated near the display,  on 
safe  door  top  right  corner  (see  Fig.  6  page  15)  and  connect  the 
printer to the safe connector with the supplied cable. 

3.

 

Enter the Service Code by pressing:    

ENTER – COMB – digit 

Service Code

 - ENTER

 

4.

 

Press 

2

 to enter the “Print Audit Trail” function. 

5.

 

The printer starts printing while the message “Print” starts blinking 
on the display . 

6.

 

After  having  printed  the  first  25  operations,  the  printer  enters  in  
stand-by position and on display  appears the word “PrintEd”; now: 

 

press 

ENTER

 to stop printing, then switch the printer off; 

 

or 

press 

any 

key 

to 

print 

another 

25 

operations. 

Then repeat point 6. 

Printing  report  starts  from  the  last  operation  and is  similar  to  the  following 
one: 

DATE 

 

HOUR  

 

TYPE OF 
OPERATION 

(i.e. OPEn) 

FURTHER INFO 

 
(i.e. wrong code) 

 

The  list  of  the  possible  printed  events  with  their  relevant  meanings  is 
reported in Appendix B. 

 

Maxi 4875 and Midi 4845 

Installation and User Manual 

Page 28 of 40 

4.10

 

Mechanical blocks during the safe closing / opening 

(mechanical error warning) 

 

Mechanical block during the safe closing 

If the mechanical block during the safe closing prevents the deadbolts from 
going  out  from  the  safe  door  for  a  time  period  of  more  than  10  seconds,  
following events will occur: 

 

the deadbolts withdraw into the safe door; 

 

a sound signal indicates the error; 

 

the message “ErrMEC” appears  on the display for 3 seconds. 

Now the safe is ready for a new operation.  

Remove  the  obstacles  preventing  the  deadbolts  from  moving  regularly  and 
close the safe again. 

 

Mechanical blocks during the safe opening 

If a mechanical block occurs during the safe opening, the message “ErrMEC” 
will appear on the display for 3 seconds.

 

In  this  case  it  is  possible  to  open  the  safe  with  the  mechanical  emergency 
key  only.  After  the  opening  with  the  mechanical  key,  each  time  a  key  is 
pressed  on  the  display  it  appears  the  word  “EMEr”  (which  indicates  an 
opening with the emergency key) and then “HELP” : it is therefore necessary 
to insert a new Guest Code. 

 

 

Summary of Contents for Maxi 4875

Page 1: ...nd dimensions of our products are approximate RISKS DURING TRANSPORT Transport of the products is always at the risk of the customer CLAIMS Any claims regarding the products must be made within 8 days from receipt of the goods Unauthorised returns will not be accepted GUARANTEE guarantees the perfect working of its products This guarantee covers the free replacement of defective items only and is ...

Page 2: ...afe 30 5 4 How to close the safe 30 5 5 Electronic input blocks 31 6 THE EMERGENCY MECHANICAL KEY 32 6 1 How to open with the emergency mechanical key 33 6 2 Emergency key duplication 33 7 OPTIONALS 34 7 1 Renting mode 34 7 2 Power supply from the electrical mains 34 7 3 Internal plug for laptop and mobile phone recharge 35 7 4 Electronic Security Key 35 7 5 Hand held printer 35 APPENDIX 36 Maxi 4...

Page 3: ...ions Working temperature 0 45 C Relative humidity with no dew 0 90 RH Optional Activating kit for renting option 220 Volts converter for power supply option Recharging kit for laptops and mobile phones Emergency opening operated with one Electronic Key Hand held printer for Audit Trial printing Maxi 4875 and Midi 4845 Installation and User Manual Page 4 of 40 2 INSTALLATION The safe must be instal...

Page 4: ...s tolerance is 5 maximum in order to avoid malfunctioning of the safe It also necessary to verify that the door controlled opening and the closing work properly Fig 2 Maxi 4875 and Midi 4845 Installation and User Manual Page 6 of 40 3 FIRST USE OF THE SAFE 3 1 Insert Replace batteries 1 Open the door and unscrew with a star head screwdriver the battery case locking screw situated on the door back ...

Page 5: ...imit and for a certain period only the safe will permit a unique last opening after which the door will remain open When battery charge level becomes too low to activate the internal mechanism the safe could be opened with the mechanical emergency key only Note Electronic board memory is non volatile that is to say that stored codes are not erased if batteries are removed replaced Maxi 4875 and Mi...

Page 6: ... before the guest uses the safe How to change the Hotel Code ENTER Hotel Code ENTER ENTER ENTER ENTER Old Hotel Code ENTER COMB New Hotel Code ENTER New Hotel Code ENTER Maxi 4875 and Midi 4845 Installation and User Manual Page 10 of 40 The Service Menu includes functions for the maintenance operations The functions that can be used through the Service Menu are Clock setting Clock and day display ...

Page 7: ...m the safe could be opened with the mechanical emergency key only Visualization of the battery level ENTER ENTER ENTER Maxi 4875 and Midi 4845 Installation and User Manual Page 12 of 40 4 2 Area Master Codes VIRO system permits to combine each safe with 6 different Area Master Codes with the option to link them to a specific area or zone of the hotel thus allowing the hotel owner to build a real h...

Page 8: ... to enable the Electronic Key with the Enabling safe ENTER ENTER Area Master Code Fig 5 Maxi 4875 and Midi 4845 Installation and User Manual Page 14 of 40 A Opening of the safe with an Electronic Security Key In this working mode the Electronic Key combined with a Password specifically generated allows the opening of a safe without knowing its Guest Code It is necessary to enable the Electronic Ke...

Page 9: ...uring this procedure of association Register following details in the form Electronic Keys attribution table Appendix C the serial number of the Electronic Key printed on the key itself the description of the access zone for which the key has been associated the name of the operator to which the key will be given It is recommended to get the signature of the operator as receipt confirmation Repeat...

Page 10: ...ENTER 4 Appears the message VAL press 1 and then ENTER 5 Appears the message SVAL press 1 and then ENTER Now all the safes are ready to work with the Electronic Keys Maxi 4875 and Midi 4845 Installation and User Manual Page 18 of 40 How to enable the safe to the use of an Electronic Key with ONE SHOT function door open Note Once the safe has been enabled to the use of the Electronic Key KEY 1 it w...

Page 11: ...d with the Password allows a one shot opening only ENTER ENTER Hotel Code ENTER 3 ENTER Area Master Code Maxi 4875 and Midi 4845 Installation and User Manual Page 20 of 40 B 3 How to open a safe with one enabled Electronic Key and Password Unthread the plastic cap situated near the display on safe door top right corner and insert the Electronic Key into the proper connector see Fig 6 page 15 Press...

Page 12: ...rd donE Manual activation door open Sound1 appears then ENTER ENTER Hotel Code ENTER ENTER ENTER ENTER 9 0 ENTER ENTER ENTER ENTER ENTER Maxi 4875 and Midi 4845 Installation and User Manual Page 22 of 40 Manual disarm To disarm the silent mode repeat the above procedure up to point 3 it will appear the word Sound0 press 1 and then ENTER 5 times until donE appears on the display Automatic activatio...

Page 13: ...On the display appears Min enter minutes from 00 to 59 and then press ENTER 5 On the display appears yy enter year from 00 to 99 and then press ENTER 6 On the display appears MM enter month from 01 to 12 and then press ENTER 7 On the display appears DD enter day from 01 to 31 and then press ENTER 8 On the display appears dOnE indicating the end of the operation Maxi 4875 and Midi 4845 Installation...

Page 14: ...ration the following data are visualized Datum 1 Number of Operation OP Datum 2 Date of Operation Datum 3 Hour of Operation Datum 4 Type of Operation i e OPEn Datum 5 Further Information i e wrong code Maxi 4875 and Midi 4845 Installation and User Manual Page 26 of 40 Inside this table it is possible to move horizontally or vertically using the alphanumerical keypad as explained below To visualize...

Page 15: ...om the last operation and is similar to the following one DATE HOUR TYPE OF OPERATION i e OPEn FURTHER INFO i e wrong code The list of the possible printed events with their relevant meanings is reported in Appendix B Maxi 4875 and Midi 4845 Installation and User Manual Page 28 of 40 4 10 Mechanical blocks during the safe closing opening mechanical error warning Mechanical block during the safe cl...

Page 16: ... will be necessary to start again from point 1 3 After the 6 digits are entered the Guest Code is stored the Guest Code blinks for 5 seconds How to insert a Guest Code door open COMB New Guest Code Maxi 4875 and Midi 4845 Installation and User Manual Page 30 of 40 5 3 How to open the safe 1 Enter the Guest Code the typed digits followed by the blinking message OPEn will appear on the display 2 At ...

Page 17: ...this block lasts 10 minutes and it starts working after 15 operations even correct have been done within a time period of 5 minutes This is the willing to prevent suspect operations like the opening with the emergency key or the Master Code from being cancelled from the Audit Trail During the block any time a key is pressed it appears the message StOP15 for 2 sec followed by the remaining minutes ...

Page 18: ...ased and moreover on the display appears the message EMER followed by HELP each time a key is pressed This way the safe opening without the use of the Guest Code is underlined 6 2 Emergency key duplication only for Hotel versions with KA key Special profile keys duplication can be done at Viro S p A factory upon special request proving the right title to receive the copy of the key Maxi 4875 and M...

Page 19: ...ion has been successfully completed the message OPEnEd appears EMEr HELP Appears when a key is pressed after the safe has been opened with the mechanical emergency key and the Guest Code has been erased It is then necessary to insert a new Guest Code MAStEr HELP Appears when a key is pressed after the safe has been opened with an Area Master Code and the Guest Code has been erased It is then neces...

Page 20: ... SEtiME Set date time New date hour n tiME New date time Wrong Guest Code OPEErr code Code error code Wrong Master Code MASErr code Master error code Maxi 4875 and Midi 4845 Installation and User Manual Page 38 of 40 DESCRIPTION OF THE OPERATION DISPLAYED MESSAGE PRINTED MESSAGE Wrong Hotel Code HC Err code H Code error code Wrong Service Code SC Err code S Code error code Mechanical block during ...

Page 21: ...Page 39 of 40 APPENDIX C Electronic Keys Attribution Table DATE OPERATOR NAME SERIAL NUMBER OF ELECTRONIC KEY ACCESS ZONES OPERATOR SIGNATURE Maxi 4875 and Midi 4845 Installation and User Manual Page 40 of 40 APPENDIX D Example of an Opening Archive Table ...

Page 22: ...42 of 40 ELECTRONIC SAFES FOR HOTEL Maxi 4875 and Midi 4845 Installation and User Manual cod 2 0 4845 493 00 410 rev E 11 12 2008 Viro S p A via Garibaldi n 4 40069 Zola Predosa Bologna ITALY Tel 39 051 6176511 ask for after sales service Fax 39 051 755079 Fax after sales support 39 051 6176627 www viro it e mail viro viro it ...

Reviews: