Virginia Controls, LLC
MH-3000 User Manual, 1_03C10-VC
Page 86
6.2.5.9
Description of Bit Feature Settings
The following features are combined into the Bit Features 1 through 10. Refer to the
sheet MH-3000 Settings in the schematic to see the settings and features provided for each
particular job. The following Settings are standard.
•
Disable Fire Service
–
Turn this feature on to disable Fire Service. This feature should
be turned on if Fire Service is not provided. It may also be turned on during initial
installation, if the Smoke Sensors or Fire Switches have not yet been installed.
•
Enable 2000+ ANSI Fire Code
–
Turn this feature on to enable 2000 or later National
Fire Code. The default code is 1998 Fire Code.
•
Enable 2005+ ANSI Fire Code
–
Turn this feature on to enable 2005 or later National
Fire Code. You must also turn on the 2000+ Fire Code feature.
•
Flash Fire Light per 2005 Code
–
Turn this feature on to make the Fire Light flash
based on the requirements of 2005 and later ANSI codes. With this enabled, the Fire
Light will only flash if Fire Service was initiated by the Smoke Sensors connected to
terminal 82F (Machine Room and Hoistway Smoke Sensors). If those sensors trip after
Fire Service is already initiated, then the Fire Light will not flash.
•
Enable 2007+ ANSI Fire Code
–
Turn this feature on to enable 2007 or later National
Fire Code. You must also turn on the 2000+ and 2005+ Fire Code features.
•
Enable New York Fire Code
–
Turn this feature on to enable New York Fire Code.
•
Enable 2001 Chicago Fire Code
–
Turn this feature on to enable 2001 Chicago Fire
Code
•
Enable 1998 Chicago Fire Code
–
Turn this feature on to enable 1998 Chicago Fire
Code. This feature is not provided on programs after 11/2007.
•
Use 2 Inputs for 1998 Chicago Fire Code
–
Turn this feature on to use 2 inputs for
the Fire Inputs for Chicago 1998 Fire Code. This feature is not provided on programs
after 11/2007.
•
Enable Canadian Fire Code
–
Turn this feature on to enable 1998 Canadian B44 Fire
Code
•
Enable Bldg Fire Sw for 2000 Fire Code
–
Turn this feature on to enable the Remote
Fire Sw on 2000 Fire Code. The input for this feature must have been assigned for this
feature to work properly.
•
Kill Independent immediately on Fire Service
–
Turn this feature on to allow Fire
Service to override Independent Service immediately.
•
No Timed Kill of Independent on Fire Service
–
Turn this feature on to prevent Fire
Service from overriding Independent Service. Independent Service must be turned off
or the doors closed by the operator to allow the car to run on Fire Service.
•
Never kill Indep. on Fire Service
–
Turn this feature on to prevent Fire Service from
overriding Independent Service. Independent Service must be turned off to allow the
car to run on Fire Service.
•
Main Fire Landing at Rear Opening
–
Turn this feature on to use the rear opening at
the designated fire opening, instead of the front opening. If there is only one opening at
the designated fire landing, then this feature will have no effect.