The interface module IM053-1DN00 is a head station for the SLIO
peripheral system with an DeviceNet interface.
Over the DeviceNet interface the input data can be read and output data
written, which parameterization system, as well as updates be
accomplished.
•
Group 2 only Device
- employs the predefined connection set
•
Poll only Device
- no BIT STROBE mode support
- no CHANGE OF STATE support
- Profile Generic Device
•
Configuration via DIP switch:
- DeviceNet address (0 ... 63)
- Attitude of the baud rate for DeviceNet slave
•
supports all baud rates: 125, 250 and 500kbit/s
•
Configuration of 64 peripheral modules
•
max. 255 in-/output data
•
Configuration of the periphery modules is made by a
DeviceNet manager
e.g. RsNetWorx from Allen-Bradley
For parameterization and for the access to the diagnostics data the data
type SHORT_STRING is used. Please consider that your DeviceNet
manager supports this type of data.
Type
Order number
Description
IM 053DN
VIPA 053-1DN00 DeviceNet coupler for System SLIO
Features
Order data
Summary of Contents for SLIO IM 053-1DN00
Page 1: ...VIPA System SLIO IM 053 1DN00 Manual HB300E_IM RE_053 1DN00 Rev 11 21 May 2011...
Page 4: ...Contents Manual VIPA System SLIO ii HB300E IM RE_053 1DN00 Rev 11 21...
Page 8: ...Safety information Manual VIPA System SLIO 4 HB300E IM RE_053 1DN00 Rev 11 21...
Page 28: ...Chapter 1 Basics and Assembly Manual VIPA System SLIO 1 20 HB300E IM RE_053 1DN00 Rev 11 21...