background image

V20BVCBK

5

User Manual

The room for installing the appliance must be at least 1 cubic metre per 8 grams of

refrigerant. The refrigerant quantity contained in this appliance is listed above in

grams; it is also noted on the Rating Plate of the appliance.

It is hazardous for anyone other than an Authorised Service Person to carry out

servicing or repairs to this appliance.

– WARNING: Keep ventilation openings in the appliance enclosure or in the built-in

structure clear of obstruction.

– WARNING: Do not use mechanical devices or other means to accelerate the defrosting

process, other than those recommended by the manufacturer.

– WARNING: Do not damage the refrigerant circuit.

– WARNING: Do not use electrical appliances inside compartments of the appliance.

– WARNING: In Queensland Australia the authorized person must hold a Gas Work

Authorisation for hydrocarbon refrigerants, before carrying out servicing or repairs which

involve the removal of covers.

The environment and personal safety must be considered when disposing of this appliance.

Please ensure the appliance is taken to a recycle center for safe recycling. DO NOT

dispose of the appliance in land fill as the insulation and refrigerant gas contained in these

appliances are flammable.

Allow 24 hours before switching on the Beverage Center. During this time we

recommend that you leave the door open to clear any residual odors.

BEFORE LOADING & PLUGGING IN THE BEVERAGE CENTER

Important: All models without front venting (air opening) are strictly for free standing

only. ( see technical chart)

Recommendations:

The location you have selected for your Beverage Center should:

- be unencumbered and well ventilated;

- be well away from any heat source and direct sunlight;

- not be too damp (laundry, pantry, bathroom etc.);

- have a flat floor;

- have a standard and reliable electricity supply (standard socket to country standards,

linked to the ground), it is NOT recommended to use a multi-socket or extension lead.

- have a surge protector fitted to the electrical outlet;

- away from the microwave oven. Certain microwave ovens do not have wave interference

shield. When placed within 1 meter vicinity of the Beverage Center, they may affect the

operation of the Beverage Center.

Summary of Contents for AL-V40BVC

Page 1: ...User Manual vintec com V20BVCBK...

Page 2: ...V20BVCBK 2 User Manual...

Page 3: ...e to the requirements in this manual may result in personal injury property damage and affect your ability to make a claim under the Vintec manufacturer s warranty provided with your product Products...

Page 4: ...nstruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance R600A WARNINGS The following models...

Page 5: ...when disposing of this appliance Please ensure the appliance is taken to a recycle center for safe recycling DO NOT dispose of the appliance in land fill as the insulation and refrigerant gas contain...

Page 6: ...tely understood If the supply cord is damaged it must be replace by a qualified person in order to avoid electrical hazard Installing your Beverage Center Unpack and remove all of the protection and a...

Page 7: ...restart the Beverage Center after having it shut off for a long time there will be a few degrees variance between the temperature you have selected and the one indicated on the LED readout This is nor...

Page 8: ...taking note of the following if you do not have enough bottles to fill your Beverage Center it is better to distribute the load throughout the Beverage Center so as to avoid all on top or all below t...

Page 9: ...enter and the actual temperature of the Beverage You will need to wait approximately 12 hours before noticing the effects of temperature adjustment due to the critical mass within a full Beverage Cent...

Page 10: ...ansferred from the compressor and evaporates any condensation that has collected in the pan Part of the remaining water is collected within the beverage center for humidity purposes This system enable...

Page 11: ...BVC 4 Remove decorative nail 8 from left top of cabinet and install spare top hinge Left 7 at left top of cabinet with 3 screws Fig D 5 Following the above procedure install the spare lower hinge to t...

Page 12: ...e rear A ventilation grid needs to be installed in this 30mm clearance area at the rear For good ventilation it is necessary to install a grill with a minimum size of 200x40mm at the top of the back w...

Page 13: ...V20BVCBK 13 User Manual Front View Front View V20 Cross section VENT SPECIFICATIONS Front View V40 Front View V26 Front View V20 400mm...

Page 14: ...se a power surge protector to avoid problems of this nature 10 Please see detailed dimensional diagrams in the preceding pages Please note The preceding diagram is for the 85mm plinth recess models Fu...

Page 15: ...0 Dimension and Installation Guide vintec com au 1800 771 776 2018 Electrolux Home Products Pty Ltd ABN 51 004 762 341 VDIM_V20BVCBK_DimSheet 40 Beer Bottle Beverage Centre V20BVCBK FRONT VIEW SIDE VI...

Page 16: ...longer period of power failure do take steps to protect your beverage 10 10 30 Fr ont View Sid e Vi ew Top Vi ew Irrespective of the cause if you notice either abnormal temperature or humidity levels...

Page 17: ...erly Turns on and off frequently The room temperature is hotter than normal A large amount of contents has been added to the Beverage center The door is opened too often The door is not closed complet...

Page 18: ...including failure to properly maintain or service iii improper negligent or faulty servicing or repair works done by anyone other than an Electrolux authorised repairer or ASC iv normal wear and tear...

Page 19: ...V20BVCBK 19 User Manual...

Page 20: ...om au 2018 Electrolux Home Products Pty Ltd ABN 51 004 762 341 VMAN_V20BVCBK_Jun18 Stay in touch and share your user experience by following us vintecclub Service and support 1800 771 776 concierge vi...