OPERATION ANOMALIES
Ensure that there is power to the electrical supply plug by connecting another electrical
appliance to it. Check fuse, if any. Make sure that the door is closed properly.
If your beverage center appears to be malfunctioning, unplug it and contact your
VINTEC
’
s
after sales service. Any intervention on the cold circuit should be performed
by a refrigeration technician who should carry out an inspection of the circuit sealing
system. Similarly, any intervention on the electrical circuit should be performed by a
qualified electrician.
Notes: Any intervention performed by a non authorized technicians by Vintec will lead to
the warranty being considered as null and void.
POWER FAILURES
In the event of a power interruption, all previous temperature settings are automatically
erased and it will revert to a preset temperature setting .
Most power failures are corrected within a short period of time. An hour or two’s loss of
power will not affect your beverage center temperatures. To avoid sudden change of
temperature while the power is off, you should avoid opening the door. For longer period
of power failure, do take steps to protect your beverage.
524
295
30
85
0
82
0
10
10
30
30
554
30
52
4
55
4
Fr ont View
Sid e Vi ew
Top Vi ew
315
Irrespective of the cause, if you notice either abnormal temperature or humidity
levels inside your beverage center, be reassured that only long and frequent exposure
to these abnormal conditions can cause a detrimental effect on your beverage.
TROUBLESHOOTING GUIDE
Common problems may easily be solved, saving you the cost of a possible service call.
Please read carefully the instruction manual and revert to troubleshooting guide chart.
PROBLEM
POSSIBLE CAUSE
Beverage center does not operate.
Not plugged in.
The appliance is turned off.
The circuit breaker tripped or the fuse is broken.
Beverage center is not cold enough.
Check the temperature control setting.
External environment may require a higher setting.
The door is opened too often.
The door is not closed completely.
The door gasket does not seal properly.
Turns on and off frequently.
The room temperature is hotter than normal.
A large amount of contents has been added to the
Beverage center.
The door is opened too often.
The door is not closed completely.
The temperature control is not set correctly.
The door gasket does not seal properly.
The light does not work.
Not plugged in.
The circuit breaker tripped or a blown fuse.
The light is out of order.
The light button is “OFF”.
Vibrations.
Check to assure that the Beverage Center is level.
The Beverage center seems to make
too much noise.
The rattling noise may come from the flow of the
refrigerant, which is normal.
As each cycle ends, you may hear gurgling sounds
caused by the flow of refrigerant in your Beverage
center.
Contraction and expansion of the inside walls may
cause popping and crackling noises.
The Beverage Center is not level.
The door will not close properly.
The Beverage Center is not level.
The door was reversed and not properly installed.
The gasket is faulty. ( magnet or rubber is spoiled)
The shelves are out of position.