- 17 -
the temperature controller will turn on the compressor and fan motors. Once the
selected temperature is sensed, the controller will turn off the cooling unit.
A. Resistance
1. Unplug WINE-MATE cooling unit or disconnect power.
2. Disconnect the red and white wires connected to the input 7 and 8 of the
temperature controller.
3. Touch and hold one ohmmeter probe to one terminal on the temperature
controller, then touch and hold the other probe to the other terminal.
4. The ohmmeter shall show a reading of 600
Ω
±
10%.
5. Reconnect the wire connector to the temperature controller.
B. Input
Live
Voltage
Figure 3-4A (3 button controller)
Figure 3-4B (5 button controller)
Figure 3-4
Summary of Contents for WINE-MATE VINO3500HZD