- 12 -
5. Place piercing valves onto the process tubes and discharge the refrigerant
into an approved R134a recovery system.
6. Use a tubing cutter to remove the suction line and discharge line from the
compressor.
7. Remove 4 nuts (11mm) from the feet of the compressor.
8. Remove the compressor
Note: Any time the sealed system is accessed the filter-drier must be
replaced. It is best to cut the drier out of the system, then braze on a new
one.
10) Removing the Condenser
1. Unplug the cooling unit or disconnect power.
2. Remove the outer cover.
3. Remove all the upper and lower styrofoam pieces.
4. Remove the fan plate.
5. Place piercing valves onto the process tubes and discharge the refrigerant
into an approved R134a recovery system.
6. Use a tubing cutter to remove the hot gas line and liquid line from the
condenser.
7. Remove 4 rivets from the condenser.
8. Remove the condenser
10) Removing the Evaporator
1. Unplug the cooling unit or disconnect power.
2. Remove the outer cover.
3. Remove all the upper and lower styrofoam pieces.
4. Remove the fan plate.
5. Place piercing valves onto the process tubes and discharge the refrigerant
into an approved R134a recovery system.
6. Cut the capillary line and suction line from the evaporator.
7. Remove 4 rivets from the evaporator.
8. Remove the evaporator.
Summary of Contents for WINE-MATE VINO3500HZD
Page 2: ...1 SAFETY INFORMATION...
Page 8: ...7 Figure 2 3 Figure 2 4...