vinmetrica SC-100A User Manual Download Page 7

SC-100A manual 

Version 3.1c 

WARRANTIES AND LIABILITIES 

1.  

The materials provided in the kit, as described on pages 1 and 2 above, (“Materials”) are 
warranted as follows: The SC-100A instrument, electrode and non-reagent accessories are 
warranted against defects in workmanship for 24 months from date of purchase.  The reagents 
are warranted to perform as described herein up until any stated expiration date or 6 months 
after purchase, whichever is later.  THE WARRANTIES IN THESE TERMS AND 
CONDITIONS ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, 
INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY, 
NONINFRINGEMENT, OR FITNESS FOR A PARTICULAR PURPOSE, SAID 
WARRANTIES BEING EXPRESSLY DISCLAIMED. 

 
2.   

Buyer agrees that its sole and exclusive remedy against Vinmetrica shall be limited to the repair 
and replacement of Materials or parts of Materials, provided Vinmetrica is promptly notified in 
writing, prior to the expiration of the warranty period specified above, of any 
defect.  Vinmetrica’s liability for any damages due Buyer shall be limited to the purchase price 
of the Materials.  

 
3.    

VINMETRICA'S MAXIMUM LIABILITY FOR ALL DIRECT DAMAGES, INCLUDING 
WITHOUT LIMITATION CONTRACT DAMAGES AND DAMAGES FOR INJURIES TO 
PERSONS OR PROPERTY, WHETHER ARISING FROM VINMETRICA’S BREACH OF 
THESE TERMS AND CONDITIONS, BREACH OF WARRANTY, NEGLIGENCE, STRICT 
LIABILITY, OR OTHER TORT WITH RESPECT TO THE MATERIALS, OR ANY 
SERVICES IN CONNECTION WITH THE MATERIALS, IS LIMITED TO AN AMOUNT 
NOT TO EXCEED THE PRICE OF THE MATERIALS.  IN NO EVENT SHALL 
VINMETRICA BE LIABLE TO BUYER FOR ANY INCIDENTAL, CONSEQUENTIAL OR 
SPECIAL DAMAGES, INCLUDING WITHOUT LIMITATION LOST REVENUES AND 
PROFITS.  

 

 
HAZARDS AND TOXICITY 
 

 

All Materials offered by Vinmetrica are intended for use by individuals who are familiar with 

laboratory procedures and their potential hazards.  The Materials contain chemicals which may be 
harmful if misused.  Due care should be exercised with all Materials to prevent direct human contact. 
Glassware can break and chemicals can splash during experiments; 

Always

 

use safety glasses

. We 

strongly recommend using nitrile or latex gloves and wearing long pants, long sleeves and closed toed 
shoes.  Keep out of reach of children. 

 
 
 

 

6084 Corte Del Cedro Suite 105, Carlsbad CA 92011 

www.vinmetrica.com

 

(760) 494-0597 

[email protected]

 

  

Copyright 2010-20. Sportsman Consulting, LLC DBA Vinmetrica.  All rights reserved. 

Summary of Contents for SC-100A

Page 1: ...ge 5 Two 3 mL polyethylene transfer pipettes 6 One 25 mL serological pipette 7 One 100 mL polypropylene beaker Things you will need 1 Two standard AA batteries alkaline type 2 Distilled water which us...

Page 2: ...63 79 99 125 pH 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0 We recommend using a sulfite calculator for determining how much sulfite to add to your wines after taking a sulfite measurement with the SC...

Page 3: ...100A shuts off after 30 minutes If this happens unexpectedly just press the POWER button to resume from where you were 4 The SO2 electrode is attached via the BNC connector protruding from the top To...

Page 4: ...to dispense the SO2 Titrant into the top of the burette 3 Using the 25 mL pipette provided in the kit place 25 mL of wine or must in the titration beaker Figure 5 Draw sample up to the 0 mL mark then...

Page 5: ...lectrode Holder adjust it to a similar level You may add up to 20 mL water if needed 8 Verify that the current is less than 50 and the green PROCEED LED is lit If the current is greater than this and...

Page 6: ...gent and 2 mL of the Reactant solution to the vessel Remember that if you are using the transfer pipettes in the kit 2 mL is marked on the side of the neck of the transfer pipette so dispense four of...

Page 7: ...METRICA S MAXIMUM LIABILITY FOR ALL DIRECT DAMAGES INCLUDING WITHOUT LIMITATION CONTRACT DAMAGES AND DAMAGES FOR INJURIES TO PERSONS OR PROPERTY WHETHER ARISING FROM VINMETRICA S BREACH OF THESE TERMS...

Page 8: ...st Mode hold the POWER button down 5 10 seconds until the instrument shuts off If the device does not shut off after 10 seconds of holding down the button move to the next section by releasing then pr...

Page 9: ...2 pH CAL values None only firmware v3 0 6 and later NA Displays current CAL values for pH 7 and 4 in mV Pressing ENTER cycles between these If a pH CAL reset has been done displays CAL value for pH 3...

Page 10: ...r this type of wine molecular SO2 pH is your value mg L Redo the calculation using this value for desired free SO2 level if required Enter this value in the Desired level of free SO2 box Press Calcula...

Page 11: ...ulated I m getting strange results in SO2 mode how do I know if my instrument is working correctly For SO2 measurements with the SC 100A there are several quick tests you can do to make sure the instr...

Page 12: ...connector to its outer metal sheath The device should indicate STOP with its red LED and buzzer or beeper and the current should go to 1999 If this does not happen there may be a problem with the ins...

Reviews: