Installation & User Manual
System CTB-100V
43
Volume control
Pos.
Operation Requirement
Tested, ok
32
Adjust sound pressure level, to convenient level if necessary
Master volume line 1-5, 6-10, 11-15, 16-20
Ref. chapter 3.8 and dwg.CU-100:lo and CU-200_lo
5.8
Trouble shooting.
Most faults can be related to following problems
Important! Use this trouble shooting together with chapter 3 Installation and Configuration Procedure
Problems when operating from operation panels.
Pos.
Failure event
Description / Indication
Recommended Action
No voltage measured on terminal block
X7 no.1-2 in the CU-unit
1.Check 24V DC mains power
supply or power supply SPS-4
1
The whole system is shut
down.
No light indication in CTB-
panels.
Correct voltage 24 – 32VDC measured
on terminal block X7 no.1-2 in the CU-
unit
2. Check fuse marked F3 1AT
(Ref. dwg CU-100_lo)
2
SPS-4 power supply failure
Indication from failure contact X2
No.5-6(NO)or. X2 No.6-7 (NC)
No light in “DC ok”
Two possibilities
1. 230V AC or 115V AC failed and
have been switched to 24V DC
Emergency.
2.The power supply module has failed.
1. Check main power supply
2. Check fuse 5.0AT , terminal
marked 3
2.1 If not success, the power
module have to be repaired./
replaced.
3
Operation from CTB-panels
failed
1.
No audio message received in any
substation no. 1-10 or 11-20.
Check fuse marked “fuse 2”1.0AT
for line 1-10 and “fuse 4”1.0AT
for line 11-20
3.1
Operation from CTB-panels
failed
2
One or more operation panels failed.
One or more Indication light is active ,
one for each operation panel marked
“indication for panels” on central
unit.ref.dwg.CU-100_lo
Check all connection for actual
panel(s) The panel operate correct
when light is turned off.
Try to replace the position, if
current panels then work correct
the fault must be in the central
unit. The main board have to be
replaced or repaired.
4
Priority do not fulfil
requirement for actual
operation panel
Check if DIP switches in the
central unit marked “set priority”
is set according to chapter 3.5
5
Receive call from substation
do not fulfil requirement for
actual station.
Check if DIP switches in the
central unit marked “set receive
call” is set according to chapter
3.6
6
Public address operation does
not fulfil the requirement for
operation of SPA public
address system.
Check if DIP switches in the
central unit marked “selector for
PA-zones” is set according to
chapter 3.7
7
Level for signal from auxiliary
does not fulfil the requirement.
Adjust trim potentiometer in the
central unit marked “adj. aux.
input signal” to satisfactorily
level.see chapter 3.8.2
7.1
Level for output PA-Signal
does not fulfil the requirement.
Adjust trim potentiometer in the
central unit marked “adj. PA-
output signal” to satisfactorily
level. See chapter 3.8.2
Summary of Contents for A-100
Page 1: ...INSTALLATION USER MANUAL CTB 100V Command Talk Back Public Address System A100K10864 ...
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......