4.1.11 Emergency Public Address Operation.
In order to comply with PA-requirements, two PA call stations are required: The CTB-100V system are designed
for use with up to four operation panels that can be used as Emergency call stations. In addition one or more All
call station (Ex. Lifeboat stations) can be used as Emergency call stations.
Following functions:
•
Mute of the External Alarm System (General / Fire Alarm)
•
Operation panel with 1
st
priority, normally bridge, can override other operation panels.
Type of Operation panels/ Emergency call stations:
•
CTB-10 Operation panel 10 line selection, indoor use. Hand or gooseneck microphone.
•
CTB-10W/V01 Operation panel 10 line selection, WP. Handmicrophone only.
•
CTB-20 Operation panel 20 line selection, indoor use. Hand or gooseneck microphone.
•
CTB-20W/V01 Operation panel 20 line selection, WP. Handmicrophone only.
•
VMT-603 All call station WT with handmicrophone.
Central unit CU-200
ON
OF F
VPA-120
POWER AMPL IFI ER
100V POWER AMPLIFIER
From 1 of 4 operation panels.
•
Press the
ALL
button, the call is set up. Indicated by steady green LED
in the
ALL
button.
“EMERGENCY PA-
BUTTON”
With gooseneck microphone MB-30G CTB-10 & CTB-20
•
Press the
TALK
marked “EMERGENCY PA –BUTTON.”
•
Speak clearly into the microphone to give message.
Summary of Contents for A-100
Page 1: ...INSTALLATION USER MANUAL CTB 100V Command Talk Back Public Address System A100K10864 ...
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......