8
A100K10676
IP DECT Deployment on Ships
Synchronization Chain with Secondary Sync Ways
Figure 5
No. 0 is the Sync Master (may be numbered 0 to 255).
-
No. 10 and No. 20: Primary and secondary sync on No. 0.
-
No. 11: Primary sync on No. 10 and secondary sync on No. 21.
-
In the example above, base station No. 10 is down. Consequently, base
station No. 11 must use the secondary sync way on base station No. 21.
Figure 6
Sync Chain showing Primary & Secondary Sync Ways
No. 0
●
is the Sync Master (may be numbered 0 to 255).
Green line
●
: Shows the primary sync ways.
Red line
●
: Shows the secondary sync ways.
For more information, please refer to the
IP DECT 6000 System Installation &
Configuration Guide
.