Use the button to move to the previous item in the programming
menu.
N.B.: to operate correctly, all the other configurations must be set to
default, except possibly the Horizontal / Vertical installation which
must be the same as switchboard 40510 with which the 69AM/T
will be used.
When using the Selector 69AM as a "Switchboard CCTV" using a
switchboard 40510 with FW >= 1.22 you can associate the 40510
with a camera (the 1 of the 69AM). One 69AM == one 40510. The
camera cannot be shared and the 69AM cannot be used for other
purposes. The 69AM should be installed on the same bus side of the
40510 as any routers / separators, but always before the 69MX since
it works like an entrance panel. In the 69AM, indicate the number
of the switchboard associated with it (Horizontal ID/Vertical ID). Do
not perform other configurations, except for Horizontal / Vertical.
In the switchboard, installer menu, enable the use of the camera.
When the switchboard (CdP) calls an internal unit, the receiver
immediately sees the video of the caller. In the case of two CdPs,
both fitted with a camera, the call is audio.
Note: If the ID is as CCTV, the ID as an Outdoor Unit is hidden if
read with 950C, and if you reconfigure 0 in CCTV again the ID as
outdoor unit reappears.
If the ID is as CCTV, operation as CCTV prevails over the two
other possible configurations as Entrance Panel ID and as Verti-
cal Device ID.
4.3B - Installation
You choose the installation mode for the electronic unit:
for
Vertical Installation or
for Horizontal Installation.
Default: Vertical
Note:
Exiting the configuration and returning the electronic unit to
rest forces sorting the contacts list.
Note:
When going from Horizontal to Vertical installation congru-
ence with other existing settings is checked. If there are any of
them that in the Vertical configuration are no longer valid, the
electronic unit will show this with a message regardless of the lan-
guage and with a numerical code:
To confirm the move from Horizontal to Vertical, that in this case
involves automatic deletion of incompatible settings, depress the
button. With
you cancel the procedure, leaving the elec-
tronic unit in Horizontal mode and without losing the settings.
4.3C - Initial ID
This item appears only if the Horizontal configuration has been
selected. It is necessary to indicate the first ID in the range of
the (video) door entry units for which some configurations can be
made in the electronic unit. These are: enabling for use of F1 /
F2, self-start.
Default: 1
4.3D - Final ID
This is the same thing as paragraph 4.3C except that it refers to
the last ID in the same range.
Default: 1000
N.B.:
the range of the ensuing window must be equal to or less
than 1000 internal units managed in accordance with the number
of IU per router (see table 3). If it is not, the electronic unit will
automatically correct the error, taking it to the maximum value per-
mitted according to table 3, and it will warn the user to check the
other end in order to be sure of the automatically corrected value
and if necessary modify it to better suit your needs.
4.3E - IU per Router
Configure the entrance panel indicating how many indoor units (IU)
are connected at most after each router. The maximum number of
all routers in the system should be indicated.
The number of IU per router is automatically optimised by the
entrance panel so as to exploit the address as much as possible.
The total number of routers that can be managed by the switch will
therefore be obtained from:
Router Number = 1000 / [IU per Router]
Where 1000 is the number of IU that a single switch manages for
the following functions:
• Enabling / disabling
• Self-start
For example with IU per Router = 50 you will be able to manage
up to 20 routers. In some configurations you can add an additional
router that covers the missing IU for a total of 1000.
The minimum of IU per Router is 31. There are 32 routers with
31 IU at most.
The maximum number of IU per Router is 200. In this case return
to the default configuration which envisages 5 routers.
Without prejudice to the fact that for each router the IU continue
to have IDs from 1 to 200, in the case of router 1, and then adding
multiples of 200 for the other routers, now the entrance panel deals
with a larger number of routers but limited to the first IU whose
number was selected with the present programming.
For example the situation for the default 50 IU per router is as follows:
ROUTER NUMBER
FROM ID
TO ID
1
1
50
2
201
250
3
401
450
4
601
650
…
19
3601
3650
20
3801
3850
Default: 200
IU distribution per Router (see Table provided on the follow-