NT-50906901-KSDR-ECOWATT-48-88-120-AN-170907
3/68
ENGLISH
10. MAINTENANCE................................................................................................................................ 64
10.1 Prior precautions .................................................................................................................... 64
10.2 Maintenance frequency .......................................................................................................... 64
10.3 Maintenance/replacement of the fresh air fi lter ..................................................................... 64
10.4 Casing maintenance ............................................................................................................... 65
10.5 Maintenance/replacement of the fan ...................................................................................... 65
10.6 Maintenance/replacement of the electric heater..................................................................... 65
10.7 Replacement parts ................................................................................................................. 66
10.8 Maintenance/replacement of the water coil ............................................................................ 66
10.9 Replacement of the CORRIGO controller battery .................................................................. 67
11. WASTE MANAGEMENT .................................................................................................................. 67
11.1 Treatment of Packaging and non-hazardous waste ............................................................... 67
11.2 Treatment of professional WEEE ........................................................................................... 67
1. GENERAL POINTS
1.1 Warnings
This product has been manufactured in compliance with a number of technical safety rules and regula-
tions, according to EC standards. The EC declaration, along with the instructions, can be downloaded from
the website www.vim.fr.
Before installing and using this product, please read these instructions carefully as they contain signifi cant
guidelines for your safety and the safety of users during the installation, commissioning and maintenance
of this product.
Once you have installed the product, attach these instructions to the machine so that they are available for
subsequent consultation.
This product must be installed (implementation, wiring, commissioning, maintenance) and all other in-
terventions must be performed by a professional in application of any applicable safety trade standards,
regulations and rules.
The installation must conform to the requirements in relation to Electromagnetic Compatibility and the Low
Voltage Directive.
VIM may not be held responsible for any bodily injury and/or damage to property caused in the event that
the safety guidelines are not respected or if the product is in any way modifi ed.
The KSDR ECOWATT
®
single fl ow units are intended for single air fl ow ventilation and air handling appli-
cations in kitchens or tertiary buildings.
Indoor (recommended) or outdoor installation:
• Max. permanent environment temperature:
-
-25°C/+60°C for size 48.
-
-25°C/+50°C for size 88.
-
-25°C/+40°C for size 120.
• To prevent any damage to electronic components (very low temperature, condensation), the safety
switch located on the front panel must be kept in the "ON" position with the exception of any main-
tenance periods.
• Relative humidity: max. of 95% without condensation.
• Potential explosive atmosphere: N/A
• Atmosphere with low salinity, without any corrosive chemical agents.