COMPONENT TESTING INFORMATION
Illustration
Component
Teat
Procedure
Result
Broil Burner
Verify gas is supplied.
Proper orifice installed for
Natural or LP.
Check for damage to screen.
Replace if punctured or torn.
Pressure regulator Verify gas pressure (WPC).
5" Natural
If on LP service verify gas
10" LP/Propane
supply conversion.
Norton Ignitor
Test for voltage at terminals.
120 VAC
Test for the amount of
3.2 --3.6 Amps
amperage in the circuit
(Ignitor may glow but not
have sufficient amperage to
open valve).
Gas valve
Disconnect wiring to valve
Measure resistance on bake
circuit.
Continuity Do not attempt to open
Measure resistance on broil
valve with 120 VAC
circuit
Continuity
Shut off valve
Check to verify gas supply is
turned on.
46