DISASSEMBLY PROCEDURES
To avoid the risk of electrical shock, personal injury or death, disconnect power
before servicing, unless testing requires it.
To avoid risk of personal injury or property damage this
unit requires a two man lift when lifting unit in or out of
cutout
Removing and Replacing Oven
1. Turn off power to the oven at the circuit breaker.
2. Open oven door and remove screws securing unit to
the
wall.
3. Pull oven forward out of the cabinet opening.
4. Disconnect or unplug the power cord leading from
unit to fuse box or junction box depending on unit.
5. Disconnect gas supply from unit.
6. Replace the oven using the installation instructions.
After final gas connection is made, turn on manual gas
valve and test all connections in gas supply piping and
oven for gas leaks.
To avoid property damage or serious personal injury,
never use a lighted match to test for gas leaks.
Control Panel Assembly
1. Turn off power to unit.
2. Remove screws securing top piece to the unit.
3. Mylar control panel is loose, but the ribbon cable
does not allow complete removal.
NOTE:
Mylar control panel needs to be supported
while removing rest of assembly.
4. Remove screws securing bottom trim under Mylar
panel.
5. Remove screws securing control panel bracket.
6. Lean control panel bracket forward to disconnect
wire terminals and ribbon cable.
While unplugging electrical connections, pins may be
damaged, use extreme care when disconnecting.
7. Gently pull control panel up and forward to remove
complete
assembly.
8. Reverse procedure to reassemble control panel.
ERC
1. Turn off power to unit.
2. Remove screws securing top trim piece to the unit.
3. Mylar control panel is loose, but the ribbon cable
does not allow complete removal.
NOTE:
Mylar control panel needs to be supported
while removing rest of assembly.
4. Remove screws securing ECR to control panel
bracket.
5. Gently pull ECR forward to gain access to wire
terminals.
While unplugging electrical connections, pins may be
damaged, use extreme care when disconnecting.
6. Disconnect all electrical connections from ECR and
remove.
7. Reverse procedure to reassemble.
20