Diagnostics
Error Codes
When an error occurs, the control does the following:
UÊ "«iÀ>ÌÊÃÊV>Vii`
UÊ ÀÀÀÊÃÊ`ë>Þi`
UÊ ÊÀÀÀÊLii«ÃÊiÛiÀÞÊÎäÊÃiV`ÃÊÀi}>À`iÃÃÊvÊ->LL>Ì
Ê`iÊi>Li`
To clear the error code, press the “OFF” or “CLEAR/SETTINGS” button. The beeping will stop, error code
goes away, and normal display is shown again. A restart may be attempted, however if the error condition has
not been corrected, the error will flash again.
Error Display
Detection
Door Latch
Unit in clean mode and door takes greater than one minute to lock
RTD Prob
RTD open or shorted
Cooling
Cooling fan speed input indicates the fan is not running
Meat Probe
Meat probe shorted or operation inconsistent with expected operation
No Probe
Meat probe input open
Model Header
No model header on EOC4 or incorrect model header for VDSC
Door
The door is open during CLEAN (either the door latch has failed, the door sensor has failed or the
user has opened the door immediately after selecting CLEAN before the latch can engage)
Comm
Loose communication link between EOC4 & VDSC
Key Short
Key press input seen for over 30 seconds
Keyboard
Internal disconnection sensed between the VDSC-tactile key PCB and the VDSC-display PCB
(these are 2 separate boards connected by a cable).
CLOCK/
PROBE
OVEN
FUNC
OVEN
TEMP
OFF
CLEAR/
SETTINGS
MIN/SEC
TIMER
SET
STOP TIMER NO PROBE
COOK TIME ON DELAY
HR
MIN
COOK
TIME
STOP
TIME
AM
PM
888°8
88:88
ERROR
000