Disassembly
©2012 Viking Preferred Service
33
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Stack Valve Burner Switch Removal
1. Remove the control panel assembly (see Control
2. Disconnect connectors from valve switch.
3. Pull to remove valve switch from burner valve.
4. Reverse procedure for installation.
Stack Valve Igniter Module Removal
1. Remove the control panel assembly (see Control
2. Disconnect connectors from module.
3. Remove screws and module from range.
4. Reverse procedure for installation.
Main Top Removal
1. Remove the control panel assembly (see Control
2. Remove backguard assembly (see Backguard
Assembly Removal).
3. Remove grates, burner caps, and burner heads from
each burner base assembly.
4. Remove screws from each burner base assembly.
5. Remove screws and side trim from each side of
range.
6. Lift main top from range.
Note:
Make sure to return insulation to original position
under each side trim.
7. Reverse procedure for installation.