Disassembly
©2012 Viking Preferred Service
25
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Motor Capacitor Removal
1. Access Control Board (see Access Control Board
2. Mark and disconnect wires from capacitor.
3. Remove nut, lockwasher, and capacitor from lower
mounting plate.
4. Reverse procedure for installation.
Door Assembly Removal
1. Open door completely. Place pins supplied with unit
in pin holes.
Important:
For personal safety, only use pins supplied
with unit. Pins can be ordered if needed #005116-000.
2. Remove screws and hinge trim from range.
3. Gently close door until pins stop door.
4. Lift door up and out.
Door Assembly
Adjustment Screw
Note:
If the door needs to be adjusted, loosen hinge
trim screws. Adjust the screws located between
the door and kick plate using a
5
/
32
" hex head
Allen wrench. Tighten hinge trim screws after
adjustment is made.
5. Reverse procedure for installation.
Door Gasket Removal
1. Open door and insert a narrow tool or small, flat-
blade screwdriver into the center of each clip and pry
upward.
2. Remove the door gasket from two holes in the bottom
of the door liner.
3. Reverse procedure for installation.