background image

22

Related Products

The 

VE-3x5

VE-5x5

VE-6x7

 and 

VE-5x10

 add vandal and weather resistance, as well as 

versatility to many Viking products. The 

VE-Series

 backboxes are available in black fine texture 

powder painted steel or Marine Grade 316 stainless steel. The weather resistant boxes are 
designed to be surface mounted to a wall, post, single gang box, or a 

VE-GNP

 gooseneck 

pedestal. 

Note:

 The 

VE-3x5

 is not compatible with the 

VE-GNP 

pedestals and is not available in 

stainless steel.

  

The 

VE-3x5

 is designed to be used with the 

E-40-EWP 

or 

E-50-EWP

 Series entry 

phones. The 

VE-5x5

 is designed to be used with the 

E-10A-EWP, E-30-EWP, 

E-30-PT-EWP, E-60-EWP, E-65-EWP, E-70-EWP, E-75-EWP

 entry phones, the 

E-1600-20A-EWP, E-1600-20-IP-EWP,

 

E-1600-30A-EWP 

and

 E-1600-30-IP-EWP

 

emergency phones, as well as the 

W-1000-EWP

 and 

W-3000-EWP

 handsfree 

doorboxes.  The 

VE-6x7

 is designed to be used with the 

K-1700-3-EWP 

and

 

K-1705-EWP

 entry phones and the 

VE-5x10

 is designed to be used with the 

K-1900-7-EWP

 and the 

K-1900-8-EWP

 vandal resistant phones.  

The 

VE-GNP

 gooseneck pedestals are designed to be used with the 

VE-5x5

VE-6x7

 and 

VE-5x10

 backboxes and are ideal for drive up 

communications. 

Note:

 The 

VE-3x5

 is not compatible with the 

VE-GNP 

pedestals.

  The 

VE-PNL

’s are 

VE-Series 

backboxes with a blank 

aluminum panel. The user can customize the clear-coated aluminum panel to mount an 

PRX-1

 card reader, 

PRX-2 

keypad or switch.  The 

kits come complete with box, gasket, panel and screws. Model numbers that end with “SS” are stainless steel version. 

Note: 

The use of 

magnets to mount the 

VE-Series

 enclosure to a metal surface can affect the operation of the enclosed product.

VE-3x5

VE-5x5

VE-6x7

VE-5x10

VE-5x5-PNL-SS

VE-6x7-PNL-SS

VE-5x10-PNL-SS

VE-5x10-SS

VE-5x5-SS

VE-5x10-PNL

VE-5x5-PNL

V

E

-G

N

P

-2

V

E

-G

N

P

-I

G

V

E

-G

N

P

-S

S

V

E

-G

N

P

For more information, see DOD 424

Surface or Pedestal Mount Viking Products While 

Maintaining Weather and Vandal Resistance

Add Panel Lighting to Your Viking VoIP Entry Phone

The 

VE-LIGHT

 kit adds bright LED illumination to any VoIP entry phone that is housed 

in a Viking 

VE-5x5

VE-6x7

 or 

VE-5x10

 enclosure.  

The stainless steel bracket is easily mounted using existing holes and hardware. Two 
bright white LEDs are used as the light source, so there are no filaments to break or 
bulbs to burn out.  

12 VDC power adapter included. Any power source between 12 and 24 volts, AC or DC 
can be used to supply the 

VE-LIGHT

 with power. 

For more information, See 

DOD 428

.  

VE-LIGHT shown right with Viking 

E-30-IP and VE-5x5 (not included)

Summary of Contents for E-20TF-IP

Page 1: ...SE TX with auto cross over Regulatory Compliance FCC Part 15 Canada ICES 3 Class A CE except for E 20TF IP and E 20TF IP EWP Connections 1 RJ45 10 100 Base T 3 gel filled butt connectors Installation...

Page 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Page 3: ...Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer...

Page 4: ...LED To Motion Sensor Rear PCB View of E 20 30 32TF IP Entry Phone Green Green Yellow Yellow Power typically not required for gate controllers Doorstrike Magnetic Lock 120V AC Connect to Optional Doors...

Page 5: ...5 22 3 25 Rear View of VE 5x5 not included 5 0 Typical 2 0 2 x 0 43 slots for single gang box 4 0 2 x 0 43 slots for double gang box 3 0 3 3 3 0 Wall Stud Front View of Plastic Rough In Box included V...

Page 6: ...uded 5 0 Typical Peel paper liner and adhere gasket to back of panel centering over mounting holes Caution For rough surfaces ie brick stucco etc additional caulking may be required Laser Etched Graph...

Page 7: ...5 7 8 9 10 11 12 6 STATUS LED Optional Viking model RC 4A Secure Remote Relay Controller see page 8 DOD 582 y PC Programming Download and install the programming software 1 Go to www vikingelectronics...

Page 8: ...allowing you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected t...

Page 9: ...Settings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values fo...

Page 10: ...t will start slow flashing the LED when your hand is detected After 3 seconds 2 beeps should be heard and the LED will start fast flashing Immediately remove your hand from covering the sensor LED sho...

Page 11: ...ctory set to 5 20 16 Microphone Volume 0 9 0 Auto factory set to 5 21 17 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 22 17 In Band Audio Call Progress Enabled Disabled factory set...

Page 12: ...erver and alternate SIP server will be limited to 31 characters Note If outbound proxy is not required enter the SIP server IP address into the Outbnd Proxy field 2 SIP Server When set to the Peer to...

Page 13: ...y personnel to identify the location of the caller and is given out when the receiving party presses a Q This ID number is transmitted as In Band DTMF This can be cleared out by leaving the field blan...

Page 14: ...or from the Emergency Entry phone This mode is useful for turning on IR flood lights VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activate t...

Page 15: ...ressing the button again after the call has been initiated will not terminate the call Factory Setting Enabled 17 Alternating Switch Action Panic Button Mode When set to Ring or Ring with AGC The Entr...

Page 16: ...rnatively the microphone can be placed in the Auto Automatic Noise Cancelling mode With the mic in the Auto mode when background noise increases the mic gain will automatically decrease When backgroun...

Page 17: ...o answer require the callers to dial the access code in order to transmit a page activate the relay or activate the optional RC 4A relays Factory Setting Auto Answer Disabled Inbound SIP calls are not...

Page 18: ...ifferent modes Factory Setting Entry Phone OFF Mode Useful for silent monitoring applications In this mode the motion sensor LED will not light during normal operation It will only flash ON OFF Blue i...

Page 19: ...e relay in the Doorstrike Mode when the push button swith is pressed the relay will be activated to open the door 42 REX Input 36 IP Firmware If new Entry Phone firmware is available after opening the...

Page 20: ...Remote Access Operation Commands Feature Tone Tone Command Description Activate Relay QQ or ___ ___ Momentarily activate relay 1 or 2 digits factory set to QQ Un Latch Relay Q0 Un latch deactivate th...

Page 21: ...netic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Page 22: ...ommunications Note The VE 3x5 is not compatible with the VE GNP pedestals The VE PNL s are VE Series backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to mou...

Page 23: ...to the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the l...

Reviews: