8

B.  Manually Muting SIP / Network Failure Alarm Beeps

 (3 beeps repeated every 30 seconds)

With the unit connected and powered (RJ45 Green LED on and Yellow LED off or blinking) it will output 3 beeps every 
30 seconds and turn the Motion Sensor Blue LED on and off once per second indicating a SIP registration failure, failure 
to receive an echo reply from pinged gateway or Ethernet connection failure. You can manually disable the beeps by 
holding your hand over the motion sensor for 5 seconds (2 beeps will then be heard) or by clicking the “Mute Alarm 
Until Next Failure” tab in the Viking VoIP programming software. The LED will continue to flash allowing you to trouble 
shoot the failure.

A.  Connect / Disconnect

Open the “Viking IP Programming” software on the PC and the start screen shown below will appear.  Any Viking IP 
phones that are connected to the network will appear on the list.  Simply select the Entry Phone on the list and click on 
the “Connect” button at the bottom or double click the selected phone.  If the security code of the selected phone is still 
set to default (845464), the PC software will not require entering a security code to connect to the phone.  Entry Phone’s 
have a default name of “VIKING_MK64_Vik02”, so if many phones are connected to the same network that all have 
the default name, MAC addresses must be used to identify each phone. 
When finished programming, click on the “Disconnect” button at the bottom.  Closing the program will also automatically 
disconnect the unit. 

Summary of Contents for E-20TF-IP

Page 1: ...SE TX with auto cross over Regulatory Compliance FCC Part 15 Canada ICES 3 Class A CE except for E 20TF IP and E 20TF IP EWP Connections 1 RJ45 10 100 Base T 3 gel filled butt connectors Installation...

Page 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Page 3: ...Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer...

Page 4: ...LED To Motion Sensor Rear PCB View of E 20 30 32TF IP Entry Phone Green Green Yellow Yellow Power typically not required for gate controllers Doorstrike Magnetic Lock 120V AC Connect to Optional Doors...

Page 5: ...5 22 3 25 Rear View of VE 5x5 not included 5 0 Typical 2 0 2 x 0 43 slots for single gang box 4 0 2 x 0 43 slots for double gang box 3 0 3 3 3 0 Wall Stud Front View of Plastic Rough In Box included V...

Page 6: ...uded 5 0 Typical Peel paper liner and adhere gasket to back of panel centering over mounting holes Caution For rough surfaces ie brick stucco etc additional caulking may be required Laser Etched Graph...

Page 7: ...5 7 8 9 10 11 12 6 STATUS LED Optional Viking model RC 4A Secure Remote Relay Controller see page 8 DOD 582 y PC Programming Download and install the programming software 1 Go to www vikingelectronics...

Page 8: ...allowing you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected t...

Page 9: ...Settings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values fo...

Page 10: ...t will start slow flashing the LED when your hand is detected After 3 seconds 2 beeps should be heard and the LED will start fast flashing Immediately remove your hand from covering the sensor LED sho...

Page 11: ...ctory set to 5 20 16 Microphone Volume 0 9 0 Auto factory set to 5 21 17 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 22 17 In Band Audio Call Progress Enabled Disabled factory set...

Page 12: ...erver and alternate SIP server will be limited to 31 characters Note If outbound proxy is not required enter the SIP server IP address into the Outbnd Proxy field 2 SIP Server When set to the Peer to...

Page 13: ...y personnel to identify the location of the caller and is given out when the receiving party presses a Q This ID number is transmitted as In Band DTMF This can be cleared out by leaving the field blan...

Page 14: ...or from the Emergency Entry phone This mode is useful for turning on IR flood lights VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activate t...

Page 15: ...ressing the button again after the call has been initiated will not terminate the call Factory Setting Enabled 17 Alternating Switch Action Panic Button Mode When set to Ring or Ring with AGC The Entr...

Page 16: ...rnatively the microphone can be placed in the Auto Automatic Noise Cancelling mode With the mic in the Auto mode when background noise increases the mic gain will automatically decrease When backgroun...

Page 17: ...o answer require the callers to dial the access code in order to transmit a page activate the relay or activate the optional RC 4A relays Factory Setting Auto Answer Disabled Inbound SIP calls are not...

Page 18: ...ifferent modes Factory Setting Entry Phone OFF Mode Useful for silent monitoring applications In this mode the motion sensor LED will not light during normal operation It will only flash ON OFF Blue i...

Page 19: ...e relay in the Doorstrike Mode when the push button swith is pressed the relay will be activated to open the door 42 REX Input 36 IP Firmware If new Entry Phone firmware is available after opening the...

Page 20: ...Remote Access Operation Commands Feature Tone Tone Command Description Activate Relay QQ or ___ ___ Momentarily activate relay 1 or 2 digits factory set to QQ Un Latch Relay Q0 Un latch deactivate th...

Page 21: ...netic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Page 22: ...ommunications Note The VE 3x5 is not compatible with the VE GNP pedestals The VE PNL s are VE Series backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to mou...

Page 23: ...to the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the l...

Reviews: