VIKING
©
LED
MODEL DVA-2W
START
VOLUME
AUX
CC
COM
SPK
TAPE/
MIC IN
VIKING
©
LED
MODEL DVA-2W
START
VOLUME
AUX
CC
COM
SPK
TAPE/
MIC IN
Programming/Recording
If only one promotional message is required, the automatic record feature may be used.
Important: The internal shunt must be in the Tape position (see Installation for details).
A. Automatic Recording
1 2 3
ON
OFF
Dip Switch Settings
VOLUME
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • •
0 0 6
STOP
REWIND
RECORD
PLAY
PAUSE
MICROPHONE
EAR/SPK
Tape Player
If multiple messages are required, the manual record mode must be used.
Important: The internal shunt must be in the MIC position (see Installation for details).
B. Manual Recording From a Microphone
Notes: If the total available record time is surpassed while recording, the last recorded message will be invalid and
will not play. The LED will pulse hi/lo to indicate that the total available record time has been surpassed. To re-
record the message, remove the microphone plug from the DVA-2W, then insert again into TAPE/MIC IN. This will
clear all previous messages from memory.
Move dip switch 3 to the ON position.
Set the volume on the tape player to a
middle setting.
Using the pause key on the tape
player, cue the tape to the blank
section just prior to the message to be
recorded.
Connect the EAR/SPK output from the
tape player to the TAPE/MIC IN jack of
the DVA-2W using a double ended
1/8" audio cord. The LED will light
steady to indicate the DVA-2W is in the
record mode.
1.
2.
3.
4.
Release the pause key on the tape player. The LED will fast flash, indicating the DVA-2W has detected
incoming audio and is recording.
The DVA-2W will automatically stop recording upon detection of 3 or more seconds of silence. Remove the
audio cord to switch the DVA-2W into the play mode.
5.
6.
Single or multiple informational messages may be repeated continuously or you may use the delay time option for
adding timed intervals between messages.
D. Repetitive Information Announcements
Up To (3) 8 Ohm
Speakers
or (16) 45 Ohm
Speakers
1 2 3
ON
OFF
Dip Switch Settings
1 2 3
ON
OFF
1 2 3
ON
OFF
1 2 3
ON
OFF
= Continuous
= 15 second delay
= 30 second delay
= 60 second delay
Strap CC to COM for continuous playback
E. Single Line, 1-4 Minute Digital Announcer
LINE
IN
LINE
OUT
REMOTE ACCESS DEVICE
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
1
2
3
4
5
600
Ω
: 600
Ω
©
MODEL RAD-1
4.7 K Resistor
(not included)
In this application, the R A D - 1 (Fax Back
Document 410) will answer the line and trigger
the message on the DVA-2W to play from the
beginning.
Note: For this application, the DVA-2W requires
MSG-MOD software (contact Product Support at
(715) 386-8666).
C.O. line or analog
PABX/KSU station
Note: Using MSG-RLD software,
the delay times may be changed
to 5 minutes, 7.5 minutes, 15
minutes or 30 minutes. For more
information, contact Product
Support at (715) 386-8666.
VIKING
©
LED
MODEL DVA-2W
START
VOLUME
AUX
CC
COM
SPK
TAPE/
MIC IN