Disassembly
26
©2010 Viking Preferred Service
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Rack Support Removal
Condition Requirements:
Door Assembly Removed
1. Remove screws and rack support from holes in back
wall of oven cavity.
2. Reverse procedure for installation.
Convection Fan Cover Removal
Condition Requirements:
One Rack Support Removed
1. Remove screws and fan cover from oven cavity.
2. Reverse procedure for installation.
Smoke Eliminator Removal
Condition Requirements:
Convection Fan Cover Removed
1. Remove screws that hold the smoke eliminator to the
top, left, rear corner of the oven liner.
2. Pull down to remove smoke eliminator from oven.
3. Reverse procedure for installation.
Convection Fan Assembly Removal
Condition Requirements:
Convection Fan Cover Removed
1. Remove screws and set convection fan assembly on
oven liner.
2. Disconnect connector and remove convection fan
assembly from oven cavity.
Note:
The mounting hole pattern for the convection
fan assembly is NOT symmetrical. Line up holes
before installing.
3. Reverse procedure for installation.