60 Watt Compact Two Zone Amplifier to Drive up to 60 Paging Speakers

The 

PA-60

can directly drive up to sixty (60) 8 ohm paging speakers or one hundred (100) 70 volt or

25 volt paging speakers. Both channels can be fed the same input so the 

PA-60

can be used as a

single large amplifier, or each channel can be fed different inputs so the 

PA-60

can be used as a two

zone amplifier.

This small and lightweight chassis design is possible by utilizing new amplifier technology that is 300%
less inefficient than old designs competitors use. High efficiency means much less heat disipation,
smaller size, higher reliability, and lower cost. 

Since each input has its own gain adjustment, one zone can be turned up louder for warehouse paging
horn speakers, and the other zone can be turned down for office ceiling speakers. Two zones can also
be helpful for installations in which one group of speakers is connected to a source that provides
background music using the Viking 

PI-1A

Paging Interface unit, and the other zone provides only

paging. 

The Viking models 

CTG-1

or 

CTG-2

can be used to add clock controlled tones with paging to both

zones, or one zone can have just paging and be free of the time scheduled alert tones. The same can
be done with the Viking model 

MTG-10

in which one zone can have just paging, and the other zone

can have paging plus the 10 different siren, warble, and chime tones that the 

MTG-10

can provide.

One or two 

PA-60

’s can be added to the Viking model 

ZPI-4

four zone paging interface to provide

either 60 watts or 120 watts of total paging power in four zones. The 

PA-60

can also be used to add

additional paging power to other Viking paging products such as the 

PA-2A

PA-15

, and 

PA-30

.

The 

PA-60

’s inputs are transformer coupled so they are floating and isolated. Because of this they can

be connected to any line level audio signal, or by turning down the input gain control to unity gain, can
be connected directly to the output of another amplifier. This allows the 

PA-60

to be connected directly

to an existing paging system speaker wire run to extend the run, with up to 60 more speakers.

Add Paging, Loud Ringing and Background Music to Centrex, PABX, IP, or Key Systems

The 

PA-15

interfaces with virtually any telephone system to provide 15 watts of paging power - enough

to drive fifteen 8-ohm paging horns or speakers. This small and light weight chassis design is possible
by utilizing new amplifier technology that is 300% less inefficient than old designs competitors use.
High efficiency means much less heat disipation, smaller size, higher reliability, and lower cost.

The 

PA-15

provides 36V talk battery for interfacing with an 

FXO

or unused analog line input/trunk

port. With the flip of a switch, the unit can connect to a 

FXS

or PABX/Centrex station ring trip port or

connect to a 600 ohm paging port. When interfacing with systems that do not provide a paging contact
closure, the built-in voice activation (

VOX

) is in control. 

After paging, the 

PA-15

auto disconnects on CPC, busy signal, silence, or default disconnect timer

(helps prevent accidental paging system lock-up if phone is hung-up incorrectly). The unit will generate
adjustable loud ringing from an independent ringing analog 

FXS

/PABX/Centrex station or from a dry

contact closure. The 

PA-15

can provide background music (muted during page) if connected to an

external music source.

Add Paging and Loud Ringing with Background Music to Any Phone System

The 

PA-30

can directly drive up to thirty (30) 8 ohm paging speakers or fifty (50) 70 volt  or 25 volt paging

speakers. This small and light weight chassis design is possible by utilizing new amplifier technology
that is 300% less inefficient than old designs competitors use. High efficiency means much less heat
disipation, smaller size, higher reliability, and lower cost. 

The 

PA-30

provides loud ringing and paging to electronic key systems, 1A2 Key systems, PABX’s as

well as No-KSU phones and multi-line phones.

Paging is accomplished by connecting the 

PA-30

to a paging port or unused telephone line input (trunk

port) of nearly any phone system.

The 

PA-30

will also generate adjustable loud ringing from a ringing analog line or from a dry contact

closure.  Either a loud electronic warble, or one of three other soft chime sounds may be selected.  An
external “night transfer” switch can be added to turn loud ringing on or off in night bell applications.

The 

PA-30

eliminates the installation of multiple bells, relays and paging cards. The unit comes complete

with a power supply, and integrated 30 watt amplifier.

Summary of Contents for 40TB-IP

Page 1: ...odel BTR 3 sold separately A momentary button press will initiate a standard call and holding the button for 3 or more seconds will initiate an emergency call The remote can also be used to adjust the speaker volume The LED on the 40TB IP can be programmed to blink when there is call activity The integrated microphone enables talk back and also monitors room noise to automatically increase speaker...

Page 2: ...tem or Service Provider Ring Central Requires Authorization ID and Proxy address Vendor Infrastructure Class Softswitch PBX Proxy SBC session border controller Service Provider 3COM VCX X 3CX X Aastra X Asterisk X Atcom X Avaya Aura Communication Manager X Avaya IP Office X BlueBox X Brekeke X Callcentric X Cisco Unified Communications Manager CUCM X X Cisco Unified Communications Manager Express ...

Page 3: ...otocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or device that fulfills requests from a client This could involve the server sending a particular file requested by the client Session Initiation Protocol SIP Is a signaling communications protocol wide...

Page 4: ...vity Power typically not required for gate controllers Doorstrike Magnetic Lock 120V AC Connect to Optional Doorstrike Mag Lock Gate Controller etc Green Unit Status LED Line Out Side View Adjustable Mounting Clamps VIKING VIKING ELECTRONICS HUDSON WI 54016 60 WATT 2 ZONE POWER AMPLIFIER PWR 60 W 24 VDC MODEL PA 60 SPKRS PWR LED SPKRS LINE LEVEL AUDIO INPUT GAIN GAIN 70V OUT SPKRS SPKRS LINE LEVEL...

Page 5: ...0TB IP Ceiling Speaker can be used to remove the grill If lost a small Allen key or heavy duty paperclip bent into an L shape can be used to remove the grill by pulling close to the edge Viking model BTR 3 Remotes can be purchased separately for wirelessly activating standard and emergency calls as well as adjusting audio volume BTR 3 Button Functions Features Specifications Wirelessly trigger sta...

Page 6: ...ontroller etc 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30VDC 250VAC max For applications requiring additional security prevent intruders from removing the speaker and accessing the on board do...

Page 7: ...gramming application click on the Viking IP Programming icon on your desk top The Main screen will appear allowing the user to program any 40TB IP connected to that LAN Typical Installation on SIP Based VoIP Phone System SIP VoIP PBX or PC with SIP Server Software 100m 328 ft maximum Viking supplies Customer s Responsibility Internet 10 100 Mbps Maximum Viking 40TB IP Note A PoE extender can be us...

Page 8: ...llowing you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the network will appear on the list Simply select the 40TB IP on the list and click on the Connect button at the bottom or double click the selected phone If the security code of the selected phone is...

Page 9: ...0TB IP in the Unit Name field When finished click on the Apply button to send the IP settings to the connected unit See Examples 1 and 2 of the required fields below Step 1 Power down the 40TB IP phone by disconnecting the LAN Cable RJ45 plug Step 2 Press and hold the CALL button then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold CALL button until you hear 2 beeps approximately 6 secon...

Page 10: ...olume 0 9 factory set to 5 17 13 Microphone Volume 0 9 0 Auto factory set to 5 18 13 Talk Listen Delay VOX 1 to 9 sec factory set to 5 sec 19 13 In Band Audio Call Progress Enabled Disabled factory set to Enabled 20 13 In Band Audio Detect Sensitivity 1 9 1 min 9 max factory set to 5 power cycle unit after setting 21 13 Repeat Announcement Option 1 9 or Continuous factory set to 1 22 14 Lap Counte...

Page 11: ...o 10 multicast paging groups can be programmed into each 40TB IP speaker Each multicast group is defined by a multicast address and port number Each multicast group is assigned a priority allowing simultaneously arriving pages to be serviced based on importance A timeout check box can be selected for each paging group See Page Length Time Out under Speaker Settings to adjust the timeout from 1 to ...

Page 12: ...r phone in order to momentarily activate the relay to control a doorstrike mag lock gate controller or other device The code can contain the characters 0 9 or Q The code cannot match a relay latching command Q1 Q0 The code must be entered while the remote phone is communicating with the Speaker phone The factory setting is QQ 10 Relay Activation Command The value stored in the Relay Activation Tim...

Page 13: ... to one of the following three modes OFF Silent Monitoring Mode In the OFF mode the speaker is disabled at all times However the speaker can be enabled after communication has been established by entering touch tone command 9 The speaker will remain on for the duration of the call ON factory setting In the ON mode the speaker is enabled during In bound and Out bound calls OFF Until Answered In the...

Page 14: ...be programmed to one of 4 different cadences Normal Ring single ring 2 sec on 4 sec off factory setting Double Ring double ring 1 sec on 5 sec off 1 sec on 3 5 sec off Short Short Long triple ring 5 sec on 5 sec off 5 sec on 5 sec off 1 sec on 3 sec off Short Long Short triple ring 5 sec on 5 sec off 1 sec on 5 sec off 5 sec on 3 sec off 23 Lap Counter With the lap counter disabled factory setting...

Page 15: ...mware 32 Unit Name 33 Mute Alarm Beeps Up to a 31 character unit name can be assigned to the 40TB IP being programmed Often times the building name and entrance location near the unit are used for the name A network failure alarm will be indicated by providing 3 beeps every 30 seconds A network failure indicates the unit is not registered to the SIP server or there is a communication failure with ...

Page 16: ... SETTINGS back to their factory default settings Note This will not effect any speaker or paging settings 37 Clear IP Settings 38 Diagnostics The Diagnostics section in the Viking IP Programming can be used to test the functionality of the mic speaker and relay 35 Phone Firmware If new 40TB IP firmware is available after opening the programming software a pop up window will ask if you would like t...

Page 17: ... deactivate the relay Latch Relay Q1 Latch continuously activate the relay Disconnect Disconnects or forces the emergency phone to hang up Send ID and Play Message Q Send I D number if programmed and plays the announcement Note Latching commands must be enabled Q6 in programming and the Relay Mode must be set to Door Strike The following commands can be entered after answering an inbound call from...

Page 18: ...hat activity on a sensor input of one unit will automatically send a message across the network to activate one of the relays on the other unit Two levels of user access permit selected users to have full operational and programming rights while others have operational control but not programming capability For more info see DOD 582 Tile Bridge for Ceiling Speakers The SA TBA is a tile bridge desi...

Page 19: ... Centrex PABX IP or Key Systems The PA 15 interfaces with virtually any telephone system to provide 15 watts of paging power enough to drive fifteen 8 ohm paging horns or speakers This small and light weight chassis design is possible by utilizing new amplifier technology that is 300 less inefficient than old designs competitors use High efficiency means much less heat disipation smaller size high...

Page 20: ...o a PO Box 4 RA number on carton In large printing write the R A number on the outside of each carton being returned RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that has failed out of box within 10 days of purchase 1 Customer must contact Viking s Technical Support at 715 386 8666 to determine possible causes for the problem The customer MUST be able to step through rec...

Reviews: