Viking Electronics 40TB-IP Product Manual Download Page 10

10

Programming Features Index

DESCRIPTION

Section

Page

Connect/Disconnect

A

8

Information Phone Numbers and Emergency Phone Numbers

1

11

Security code (factory set to 845464)  

2

11

Access Code (1-6 digits, blank = disabled, factory set to 123456)

3

11

SIP Page / Call Priority VS Multicast

4

11

Multicast Paging

5

11

Multicast Page Length Time Out (factory set to disabled)

6

12

Multicast Paging Volume (0-9, factory set to 1)

7

12

Internal / External Relay (factory set to Internal)

8

12

Relay Mode (Door Strike, Outbound Call, Phone or Paging, Doorbell, Alarm Mode, Ring, Ring Flash, factory set to Door Strike)

9

12

Relay Activation Command (1 or 2 digits, factory set to 

QQ

)

NOTE: 

Relay Mode must be set to Door Strike

10

12

Relay Activation Time (0.5 - 99 sec, factory set to 5 sec)

11

12

Relay Buzz Volume (1-3 or Disabled, factory set to 3)

12

12

Relay Latch Commands (Enabled or Disabled, factory set to Enabled) 

NOTE: 

Relay Mode must be set to Door Strike

13

13

Panic Button mode (Enabled, Disabled, factory set to Disabled)

14

13

Speaker Mode (ON, OFF / Silent Monitor or OFF until Answered, factory set to ON) 

15

13

Sip Page / Phone Volume (0-9, factory set to 1)

16

13

Ring Volume (0-9, factory set to 5)

17

13

Microphone Volume (0-9, 0 = Auto, factory set to 5)   

18

13

Talk/Listen Delay (VOX) (.1 to .9 sec, factory set to .5 sec)

19

13

In-Band Audio Call Progress (Enabled, Disabled, factory set to Enabled)

20

13

In-Band Audio Detect Sensitivity (1-9, 1 = min, 9 = max, factory set to 5, power cycle unit after setting)

21

13

Repeat Announcement Option (1-9 or Continuous, factory set to 1)

22

14

Lap Counter ( 1-9 or Disabled, factory set to Disabled)

23

14

SIP Page / Call Length Time Out (disabled or 1 to 9 min, factory set to 3 min)

24

14

Inbound Call Mode (Disabled, Auto Answer, Auto Answer-Secure, Ring, Ring with AGC, Factory set to Auto Answer)

25

14

Ring Cadence (factorty set to Normal, 2 seconds on 4 seconds off)

26

14

Dial Next Number on RNA (Ring No Answer) (disabled, 1 - 9 = number of rings, factory set to 7)

27

15

Dial Next Number on Busy (disabled or enabled, factory set to enabled)  

28

15

Send ID Number as (In-Band DTMF or RFC 2833, factory set to In-Band DTMF)

29

15

LED Mode (OFF, ON, Phone or Paging, or Outbound phone, factory set to Phone or Paging)

30

15

Call LED Control (Automatic or enter 

Q

to light, factory set to Automatic)

31

15

Unit Name 

32

15

Mute Alarm Beeps

33

15

IP Firmware

34

15

Phone Firmware

35

16

Import/Export

36

16

Clear Speaker Settings

37

16

Clear IP Settings

37

16

Diagnostics (used to check mic, speaker and relay operation)  

38

16

Summary of Contents for 40TB-IP

Page 1: ...odel BTR 3 sold separately A momentary button press will initiate a standard call and holding the button for 3 or more seconds will initiate an emergency call The remote can also be used to adjust the speaker volume The LED on the 40TB IP can be programmed to blink when there is call activity The integrated microphone enables talk back and also monitors room noise to automatically increase speaker...

Page 2: ...tem or Service Provider Ring Central Requires Authorization ID and Proxy address Vendor Infrastructure Class Softswitch PBX Proxy SBC session border controller Service Provider 3COM VCX X 3CX X Aastra X Asterisk X Atcom X Avaya Aura Communication Manager X Avaya IP Office X BlueBox X Brekeke X Callcentric X Cisco Unified Communications Manager CUCM X X Cisco Unified Communications Manager Express ...

Page 3: ...otocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or device that fulfills requests from a client This could involve the server sending a particular file requested by the client Session Initiation Protocol SIP Is a signaling communications protocol wide...

Page 4: ...vity Power typically not required for gate controllers Doorstrike Magnetic Lock 120V AC Connect to Optional Doorstrike Mag Lock Gate Controller etc Green Unit Status LED Line Out Side View Adjustable Mounting Clamps VIKING VIKING ELECTRONICS HUDSON WI 54016 60 WATT 2 ZONE POWER AMPLIFIER PWR 60 W 24 VDC MODEL PA 60 SPKRS PWR LED SPKRS LINE LEVEL AUDIO INPUT GAIN GAIN 70V OUT SPKRS SPKRS LINE LEVEL...

Page 5: ...0TB IP Ceiling Speaker can be used to remove the grill If lost a small Allen key or heavy duty paperclip bent into an L shape can be used to remove the grill by pulling close to the edge Viking model BTR 3 Remotes can be purchased separately for wirelessly activating standard and emergency calls as well as adjusting audio volume BTR 3 Button Functions Features Specifications Wirelessly trigger sta...

Page 6: ...ontroller etc 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30VDC 250VAC max For applications requiring additional security prevent intruders from removing the speaker and accessing the on board do...

Page 7: ...gramming application click on the Viking IP Programming icon on your desk top The Main screen will appear allowing the user to program any 40TB IP connected to that LAN Typical Installation on SIP Based VoIP Phone System SIP VoIP PBX or PC with SIP Server Software 100m 328 ft maximum Viking supplies Customer s Responsibility Internet 10 100 Mbps Maximum Viking 40TB IP Note A PoE extender can be us...

Page 8: ...llowing you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the network will appear on the list Simply select the 40TB IP on the list and click on the Connect button at the bottom or double click the selected phone If the security code of the selected phone is...

Page 9: ...0TB IP in the Unit Name field When finished click on the Apply button to send the IP settings to the connected unit See Examples 1 and 2 of the required fields below Step 1 Power down the 40TB IP phone by disconnecting the LAN Cable RJ45 plug Step 2 Press and hold the CALL button then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold CALL button until you hear 2 beeps approximately 6 secon...

Page 10: ...olume 0 9 factory set to 5 17 13 Microphone Volume 0 9 0 Auto factory set to 5 18 13 Talk Listen Delay VOX 1 to 9 sec factory set to 5 sec 19 13 In Band Audio Call Progress Enabled Disabled factory set to Enabled 20 13 In Band Audio Detect Sensitivity 1 9 1 min 9 max factory set to 5 power cycle unit after setting 21 13 Repeat Announcement Option 1 9 or Continuous factory set to 1 22 14 Lap Counte...

Page 11: ...o 10 multicast paging groups can be programmed into each 40TB IP speaker Each multicast group is defined by a multicast address and port number Each multicast group is assigned a priority allowing simultaneously arriving pages to be serviced based on importance A timeout check box can be selected for each paging group See Page Length Time Out under Speaker Settings to adjust the timeout from 1 to ...

Page 12: ...r phone in order to momentarily activate the relay to control a doorstrike mag lock gate controller or other device The code can contain the characters 0 9 or Q The code cannot match a relay latching command Q1 Q0 The code must be entered while the remote phone is communicating with the Speaker phone The factory setting is QQ 10 Relay Activation Command The value stored in the Relay Activation Tim...

Page 13: ... to one of the following three modes OFF Silent Monitoring Mode In the OFF mode the speaker is disabled at all times However the speaker can be enabled after communication has been established by entering touch tone command 9 The speaker will remain on for the duration of the call ON factory setting In the ON mode the speaker is enabled during In bound and Out bound calls OFF Until Answered In the...

Page 14: ...be programmed to one of 4 different cadences Normal Ring single ring 2 sec on 4 sec off factory setting Double Ring double ring 1 sec on 5 sec off 1 sec on 3 5 sec off Short Short Long triple ring 5 sec on 5 sec off 5 sec on 5 sec off 1 sec on 3 sec off Short Long Short triple ring 5 sec on 5 sec off 1 sec on 5 sec off 5 sec on 3 sec off 23 Lap Counter With the lap counter disabled factory setting...

Page 15: ...mware 32 Unit Name 33 Mute Alarm Beeps Up to a 31 character unit name can be assigned to the 40TB IP being programmed Often times the building name and entrance location near the unit are used for the name A network failure alarm will be indicated by providing 3 beeps every 30 seconds A network failure indicates the unit is not registered to the SIP server or there is a communication failure with ...

Page 16: ... SETTINGS back to their factory default settings Note This will not effect any speaker or paging settings 37 Clear IP Settings 38 Diagnostics The Diagnostics section in the Viking IP Programming can be used to test the functionality of the mic speaker and relay 35 Phone Firmware If new 40TB IP firmware is available after opening the programming software a pop up window will ask if you would like t...

Page 17: ... deactivate the relay Latch Relay Q1 Latch continuously activate the relay Disconnect Disconnects or forces the emergency phone to hang up Send ID and Play Message Q Send I D number if programmed and plays the announcement Note Latching commands must be enabled Q6 in programming and the Relay Mode must be set to Door Strike The following commands can be entered after answering an inbound call from...

Page 18: ...hat activity on a sensor input of one unit will automatically send a message across the network to activate one of the relays on the other unit Two levels of user access permit selected users to have full operational and programming rights while others have operational control but not programming capability For more info see DOD 582 Tile Bridge for Ceiling Speakers The SA TBA is a tile bridge desi...

Page 19: ... Centrex PABX IP or Key Systems The PA 15 interfaces with virtually any telephone system to provide 15 watts of paging power enough to drive fifteen 8 ohm paging horns or speakers This small and light weight chassis design is possible by utilizing new amplifier technology that is 300 less inefficient than old designs competitors use High efficiency means much less heat disipation smaller size high...

Page 20: ...o a PO Box 4 RA number on carton In large printing write the R A number on the outside of each carton being returned RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that has failed out of box within 10 days of purchase 1 Customer must contact Viking s Technical Support at 715 386 8666 to determine possible causes for the problem The customer MUST be able to step through rec...